Any cross section (ACS)
Any cross section (ACS) · Zone modifiers · ISO 1101
The brands and control names mentioned belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, ISO or ASME: this is our own content, not official documentation. Legal notice.
How to interpret it
On the drawing, “◎ ⌀ 0.02 ACS |A|” states a any cross section (ACS) requirement with a cylindrical tolerance zone of ⌀ 0.02 mm, measured from datum A.
What controls
An ISO 1101:2017 modifier (and ISO 5459, when placed with a datum letter) stating that the requirement applies in any cross section, each section evaluated on its own, not to the feature as a whole. Its typical use is concentricity: «◎ ⌀ 0.02 ACS |A|» requires the centre of each section to lie within a ⌀ 0.02 circle around the reference point of that same section. Next to a datum letter («A ACS»), the datum is the centre of each section, not the common axis of the cylinder. What it does NOT do is accumulate sections: unlike coaxiality or cylindricity, a slightly tapered or bowed part can conform section by section.
How to verify
Measure several sections along the feature; in each one compute the centre of the toleranced feature and that of the datum in the same section, and check that the distance between them fits the zone (radius = t/2). Report the worst value of all sections.
Common mistakes when interpreting it
- Evaluating it as full-axis coaxiality: with ACS each section is judged on its own.
- Measuring a single chosen section and extending the result: the requirement applies in any section, so several must be sampled.
How to get it in the workshop / if it comes out of tolerance
If the frame carries ACS, inspection is section by section: on a CMM, several sections each with its own computed centre; on the shop floor, a fixed indicator in one plane while the part rotates. Do not turn it into a full-axis coaxiality measurement, which is stricter and rejects good parts.
Related symbols
Sources
- Standard: ISO 1101:2017
Other symbols in Zone modifiers
Related apps
ISO fits
Calculates indicative ISO 286 tolerances for shaft and hole, H7/g6, H7/h6, H7/k6 and H7/p6 fits with clearance, transition and interference graph.
Inspection Plans
Upload a plan, extract dimensions and GD&T with AI and export your inspection guideline in PDF or CSV.
Shop trigonometry
Workshop trigonometry: right triangle, C chamfer, Z countersink, sine bar, taper and polar→X/Y for CNC operators.