Derived feature (Ⓐ)
Derived feature (Ⓐ) · Zone modifiers · ISO 1101
The brands and control names mentioned belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, ISO or ASME: this is our own content, not official documentation. Legal notice.
How to interpret it
On the drawing, “— ⌀ 0.03 Ⓐ” states a derived feature (Ⓐ) requirement.
What controls
An ISO 1101:2017 modifier written after the tolerance value to indicate that the requirement applies to the derived feature (axis or median plane) and not to the surface, even when the frame's arrow touches the surface instead of lining up with the dimension line. It is an alternative to the classic way of pointing to the axis by aligning the arrow with the size dimension.
How to verify
Take several sections (or pairs of opposite points on parallel faces), compute the derived axis or median plane and evaluate the tolerance on that derived feature.
Common mistakes when interpreting it
- Confusing Ⓐ with datum A: it goes after the tolerance value, not in a datum compartment.
- Measuring the surface when the frame carries Ⓐ: the requirement is on the axis or median plane.
How to get it in the workshop / if it comes out of tolerance
With Ⓐ the axis or median plane is controlled: measure centres (sections on a CMM, centre between faces), not the surface. Without Ⓐ and with the arrow on the surface, the surface itself is controlled.
Related symbols
Sources
- Standard: ISO 1101:2017
Other symbols in Zone modifiers
Related apps
ISO fits
Calculates indicative ISO 286 tolerances for shaft and hole, H7/g6, H7/h6, H7/k6 and H7/p6 fits with clearance, transition and interference graph.
Inspection Plans
Upload a plan, extract dimensions and GD&T with AI and export your inspection guideline in PDF or CSV.
Shop trigonometry
Workshop trigonometry: right triangle, C chamfer, Z countersink, sine bar, taper and polar→X/Y for CNC operators.