Separate zones (SZ)

Separate zones (SZ) · Zone modifiers · ISO 1101

The brands and control names mentioned belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, ISO or ASME: this is our own content, not official documentation. Legal notice.

3×⏥0.05SZ(flatnessofthreefaces,eachoneseparately)

How to interpret it

On the drawing, “3× ⏥ 0.05 SZ (flatness of three faces, each one separately)” states a separate zones (SZ) requirement.

What controls

An ISO 1101:2017 / ISO 5458 indication added to a frame applied to several features to make clear that each one has its own zone, with no location or orientation relationship between zones. In ISO GPS it is the default behaviour when CZ is not written, so SZ is written mainly to avoid doubt or when the same group carries another row with CZ. It is the opposite of the common zone (CZ).

How to verify

Each feature is evaluated with its own fit (for example its own minimum-zone plane for flatness) and its result is reported separately. No common zone is built.

Common mistakes when interpreting it

  • Treating it as CZ and requiring all faces to fit a single common zone: with SZ each one stands alone.
  • Thinking that without SZ an ISO frame with «n×» already creates a common zone: CZ must be written to join the zones.

How to get it in the workshop / if it comes out of tolerance

With SZ each feature is measured and accepted on its own, and you may realign between one and the next. If the same group carries a second row with CZ, the relationship between features is controlled in that other row.