Heidenhain Faulty range data alarm: Incorrect probing range data

The TNC detects an invalid or out-of-limits MIN/MAX range in probing/digitizing cycles.

For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.

Control
Heidenhain
Machine
Milling, Mill-turn
Area
Program
Severity
Stop

Symptoms

  • The digitising cycle does not start.
  • FAULTY RANGE DATA message.
  • Coordenadas MIN/MAX incoherentes.

Common causes

  • MIN greater than or equal to MAX.
  • Range outside software limits.
  • RANGE was not defined before MEANDER/CONTOUR.

First safe checks

  1. 01Revisar coordenadas MIN/MAX.
  2. 02Confirm software limits.
  3. 03Define RANGE before the cycle.

What not to do

  • Do not widen the range without checking the travel.
  • Do not run it if it could hit the stops.

When to call maintenance:

Normally requires no maintenance.

Reset/rearm:

Reset tras corregir datos de rango.

Official documentation

Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.

Frequently Asked Questions (FAQ)

What does alarm Heidenhain Faulty range data mean on Heidenhain?

The TNC detects an invalid or out-of-limits MIN/MAX range in probing/digitizing cycles. It is an alarm from the Program area, and in the catalog it is listed as “Incorrect probing range data”. On the machine you notice it like this: The digitising cycle does not start, FAULTY RANGE DATA message, Coordenadas MIN/MAX incoherentes.

Why does alarm Heidenhain Faulty range data come up?

On the shop floor it almost always comes from one of these causes: MIN greater than or equal to MAX, Range outside software limits, RANGE was not defined before MEANDER/CONTOUR. Rule out the most likely one on your machine first, before touching parameters or swapping anything.

How do you clear alarm Heidenhain Faulty range data?

Reset tras corregir datos de rango. Resetting without fixing the cause first only hides the problem: Heidenhain Faulty range data trips again and, in the meantime, you keep working with the machine in bad shape.

What should I check first with alarm Heidenhain Faulty range data?

With the machine stopped and in a safe state, start with these checks: Revisar coordenadas MIN/MAX, Confirm software limits, Define RANGE before the cycle. That alone will tell you whether it is the program or whether you need to raise a maintenance job.

What should I NOT do with alarm Heidenhain Faulty range data?

With Heidenhain Faulty range data active, avoid this: Do not widen the range without checking the travel, Do not run it if it could hit the stops. Skipping any of these points is what turns a minor stop into an expensive breakdown.

When do I have to call maintenance for alarm Heidenhain Faulty range data?

Normally requires no maintenance. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.

How serious is alarm Heidenhain Faulty range data?

It is a stop alarm: the cycle will not continue until you fix the cause. It does not always mean serious damage, but it leaves the machine where it is and you have to check it before running again. Guidance reference. Always confirm the full text in the exact machine/control manual.