Back to CNC Alarms Guide

Heidenhain Touch point inaccessible alarm: Probing point not reachable

After starting a probing cycle, the point is not reached within the range defined by MP6130.

For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.

Control
Heidenhain
Machine
Milling, Mill-turn
Area
Encoder / measurement
Severity
Stop

Symptoms

  • The probing cycle is cancelled.
  • The stylus does not contact the surface.
  • Distancia recorrida supera MP6130.

Common causes

  • Badly located piece.
  • Zero wrong piece.
  • MP6130 too small.
  • Stylus not calibrated.

First safe checks

  1. 01Verify real position of the piece.
  2. 02Confirm zero piece.
  3. 03Pre-position closer to the surface.

What not to do

  • Do not increase MP6130 without understanding the impact.
  • Do not scan over an empty area.

When to call maintenance:

If MP6130 was modified without documentation or the probe does not calibrate.

Reset/rearm:

Reset after correcting pre-position or zero.

Official documentation

Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.

Frequently Asked Questions (FAQ)

What does alarm Heidenhain Touch point inaccessible mean on Heidenhain?

After starting a probing cycle, the point is not reached within the range defined by MP6130. It is an alarm from the Encoder / measurement area, and in the catalog it is listed as “Probing point not reachable”. On the machine you notice it like this: The probing cycle is cancelled, The stylus does not contact the surface, Distancia recorrida supera MP6130.

Why does alarm Heidenhain Touch point inaccessible come up?

On the shop floor it almost always comes from one of these causes: Badly located piece, Zero wrong piece, MP6130 too small, Stylus not calibrated. Rule out the most likely one on your machine first, before touching parameters or swapping anything.

How do you clear alarm Heidenhain Touch point inaccessible?

Reset after correcting pre-position or zero. Resetting without fixing the cause first only hides the problem: Heidenhain Touch point inaccessible trips again and, in the meantime, you keep working with the machine in bad shape.

What should I check first with alarm Heidenhain Touch point inaccessible?

With the machine stopped and in a safe state, start with these checks: Verify real position of the piece, Confirm zero piece, Pre-position closer to the surface. That alone will tell you whether it is the program or whether you need to raise a maintenance job.

What should I NOT do with alarm Heidenhain Touch point inaccessible?

With Heidenhain Touch point inaccessible active, avoid this: Do not increase MP6130 without understanding the impact, Do not scan over an empty area. Skipping any of these points is what turns a minor stop into an expensive breakdown.

When do I have to call maintenance for alarm Heidenhain Touch point inaccessible?

If MP6130 was modified without documentation or the probe does not calibrate. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.

How serious is alarm Heidenhain Touch point inaccessible?

It is a stop alarm: the cycle will not continue until you fix the cause. It does not always mean serious damage, but it leaves the machine where it is and you have to check it before running again. Guidance reference. Always confirm the full text in the exact machine/control manual.