Skip to content
Back to Materials Catalog

Poliamida 12 (PA12 / Nylon 12)

Ntechnical plasticPA12Indicative reference data. Always check the supplier's mill certificate (3.1) before using them on critical parts.

Strength (Rm)
45-55 MPa
Higher than 3% of the catalogue
Machinability
Excellent · 90
Higher than 50% of its family
Density
1.01 g/cm³
Higher than 2% of the catalogue
Designación PA12ISO 1874-1 PA12Alias Nylon 12Alias PA 12Alias poliamida 12Alias polyamide 12Alias GrilamidAlias RilsanAlias VestamidAlias Vestamid LAlias Ensinger TECAMID 12
See recommended Vc and feed →

Mechanical properties

Alargamiento (A%)

≥150 %

Elastic modulus (E)

1.4 GPa

Shear modulus (G)

0.5 GPa

Thermal properties

melting point

~178 °C

Temp. max. of service

80 °C

Thermal expansion

100 µm/m·K

Workshop behavior

Corrosion resistance

Very good

Less hygroscopic than PA6/PA66

Fatigue resistance

Moderate and very temperature-sensitive

It drops with the heat generated by the cut itself

Impact resistance

Very variable depending on the polymer

Check the individual file

Magnetic?

No

Vc on the lathe

245–491 m/min

Carbide, medium cut

Vc in milling

164–409 m/min

Carbide, medium cut

Achievable finish (Ra)

0.8–3.2µm

Some such as POM or PMMA allow almost optical finishing with a very sharp tool

See recommended Vc and feed →

Recommended coolant

Compressed air in most cases

Avoid coolants that attack or swell the polymer

Chip control

Long continuous chip in ductile materials (PA, PE, PP)

Powdery in materials loaded with fiber

Typical uses

  • Pneumatic tubes and fittings
  • Precision flexible parts
  • Prototipos funcionales

Machining notes and operator tips

It absorbs much less moisture than PA6, so it maintains the dimension better on precision parts.

  • Clamp the part without distorting it; many plastics are soft and an overtightened vice spoils the final dimension.
  • Use air to cool instead of liquid whenever the material allows it; prevents it from absorbing moisture or swelling.
  • Let the part stabilise at room temperature before measuring critical dimensions: the cutting itself heats it up.

Calculate weight and cost of raw bar

Estimated weight

0.317 kg

Sources

  • Standard: ISO 1874-1 · PA12
  • Standard: ISO 513:2012 · N

Materials in the same family

See the full material catalogue

Related apps