Mitsubishi M01 0030 alarm: Skip signal still on when measurement starts

Mitsubishi detects that the skip signal is still on when the measurement goes from the retract to the second probing.

For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.

The brands and control names mentioned belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, ISO or ASME: this is our own content, not official documentation. Legal notice.

Control
Mitsubishi
Machine
Milling, Turning, Mill-turn
Area
Encoder / measurement
Severity
Stop

Symptoms

  • A measuring cycle with a probe or tool setter fails.
  • The alarm comes up right after the first contact.
  • The probe is still in contact after retracting.

Common causes

  • Skip retract distance too short.
  • Probe or gauge that does not release (dirty, chips, spring).
  • Skip signal stuck or faulty wiring.

First safe checks

  1. 01Write down the cycle and the measuring axis.
  2. 02Clean the probe and the measuring surface.
  3. 03Check that the probe LED or signal goes off when it is moved clear.

What not to do

  • Do not repeat the measurement blindly with the probe in contact.
  • Do not bypass the measurement to keep producing.

When to call maintenance:

If the skip signal stays active with the probe free.

Reset/rearm:

Reset after moving the probe clear, and increase the retract if needed.

Mitsubishi manual IB-1501279(ENG)-T (M800/M80/E80 Alarm/Parameter Manual), ch. 1, p. 7: M01 0030 «Now skip on»: the skip signal is still active when going from the skip retract to the measurement; remedy: increase the retract. Excessive servo error on Mitsubishi is drive alarm 52/53 (S01/S03), not M01 0030.

Sources

  • Official manual: MITSUBISHI CNC M800/M80/E80 Series Alarm/Parameter Manual (IB-1501279ENG-T) · p. 7

Official documentation

Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.

Brand and control names belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, and this guide is not official documentation.

Frequently asked questions

What does alarm Mitsubishi M01 0030 mean on Mitsubishi?

Mitsubishi detects that the skip signal is still on when the measurement goes from the retract to the second probing. It is an alarm from the Encoder / measurement area, and in the catalog it is listed as “Skip signal still on when measurement starts”. On the machine you notice it like this: A measuring cycle with a probe or tool setter fails, The alarm comes up right after the first contact, The probe is still in contact after retracting.

Why does alarm Mitsubishi M01 0030 come up?

On the shop floor it almost always comes from one of these causes: Skip retract distance too short, Probe or gauge that does not release (dirty, chips, spring), Skip signal stuck or faulty wiring. Rule out the most likely one on your machine first, before touching parameters or swapping anything.

How do you clear alarm Mitsubishi M01 0030?

Reset after moving the probe clear, and increase the retract if needed. Resetting without fixing the cause first only hides the problem: Mitsubishi M01 0030 trips again and, in the meantime, you keep working with the machine in bad shape.

What should I check first with alarm Mitsubishi M01 0030?

With the machine stopped and in a safe state, start with these checks: Write down the cycle and the measuring axis, Clean the probe and the measuring surface, Check that the probe LED or signal goes off when it is moved clear. That alone will tell you whether it is the program or whether you need to raise a maintenance job.

What should I NOT do with alarm Mitsubishi M01 0030?

With Mitsubishi M01 0030 active, avoid this: Do not repeat the measurement blindly with the probe in contact, Do not bypass the measurement to keep producing. Skipping any of these points is what turns a minor stop into an expensive breakdown.

When do I have to call maintenance for alarm Mitsubishi M01 0030?

If the skip signal stays active with the probe free. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.

How serious is alarm Mitsubishi M01 0030?

It is a stop alarm: the cycle will not continue until you fix the cause. It does not always mean serious damage, but it leaves the machine where it is and you have to check it before running again. Mitsubishi manual IB-1501279(ENG)-T (M800/M80/E80 Alarm/Parameter Manual), ch. 1, p. 7: M01 0030 «Now skip on»: the skip signal is still active when going from the skip retract to the measurement; remedy: increase the retract. Excessive servo error on Mitsubishi is drive alarm 52/53 (S01/S03), not M01 0030.