Skip to content

Mitsubishi Z51 alarm: E2PROM error (read or write)

Mitsubishi reports that the control could not read (Z51 0011) or write (Z51 0012) its E2PROM memory.

For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.

The brands and control names mentioned belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, ISO or ASME: this is our own content, not official documentation. Legal notice.

Control
Mitsubishi
Machine
Milling, Turning, Mill-turn
Area
Power supply
Severity
Critical

Symptoms

  • System alarm Z51 on the screen.
  • Appears when saving data or at startup.
  • It repeats with the same operation.

Common causes

  • Control unit hardware failure.
  • Power loss during a write.
  • E2PROM memory damaged.

First safe checks

  1. 01Write down the subcode (0011 read, 0012 write) and the operation being done.
  2. 02Back up programs and parameters if the control allows it.
  3. 03Check whether it repeats when doing the same thing.

What not to do

  • Do not keep saving important data on a control with repeated Z51.
  • Do not swap boards without a full backup.

When to call maintenance:

If the alarm repeats with the same operation (hardware fault according to the manual).

Reset/rearm:

Reset or restart; if it comes back with the same operation, call service.

Mitsubishi manual IB-1501279(ENG)-T (M800/M80/E80 Alarm/Parameter Manual), ch. 5 «System Alarms (Z)», p. 97: Z51 «E2PROM error», 0011 read and 0012 write; if it repeats with the same operation, it is a hardware fault. Loss of absolute position is Z70 (ch. 6).

Sources

  • Official manual: MITSUBISHI CNC M800/M80/E80 Series Alarm/Parameter Manual (IB-1501279ENG-T) · p. 97

Official documentation

Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.

Brand and control names belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, and this guide is not official documentation.

Frequently asked questions

What does alarm Mitsubishi Z51 mean on Mitsubishi?

Mitsubishi reports that the control could not read (Z51 0011) or write (Z51 0012) its E2PROM memory. It is an alarm from the Power supply area, and in the catalog it is listed as “E2PROM error (read or write)”. On the machine you notice it like this: System alarm Z51 on the screen, Appears when saving data or at startup, It repeats with the same operation.

Why does alarm Mitsubishi Z51 come up?

On the shop floor it almost always comes from one of these causes: Control unit hardware failure, Power loss during a write, E2PROM memory damaged. Rule out the most likely one on your machine first, before touching parameters or swapping anything.

How do you clear alarm Mitsubishi Z51?

Reset or restart; if it comes back with the same operation, call service. Resetting without fixing the cause first only hides the problem: Mitsubishi Z51 trips again and, in the meantime, you keep working with the machine in bad shape.

What should I check first with alarm Mitsubishi Z51?

With the machine stopped and in a safe state, start with these checks: Write down the subcode (0011 read, 0012 write) and the operation being done, Back up programs and parameters if the control allows it, Check whether it repeats when doing the same thing. That alone will tell you whether it is the program or whether you need to raise a maintenance job.

What should I NOT do with alarm Mitsubishi Z51?

With Mitsubishi Z51 active, avoid this: Do not keep saving important data on a control with repeated Z51, Do not swap boards without a full backup. Skipping any of these points is what turns a minor stop into an expensive breakdown.

When do I have to call maintenance for alarm Mitsubishi Z51?

If the alarm repeats with the same operation (hardware fault according to the manual). If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.

How serious is alarm Mitsubishi Z51?

It is critical: there is a real risk of damage to the machine, the tool or a person. Leave the machine stopped, do not keep resetting it to see if it goes away, and call maintenance before producing again. Mitsubishi manual IB-1501279(ENG)-T (M800/M80/E80 Alarm/Parameter Manual), ch. 5 «System Alarms (Z)», p. 97: Z51 «E2PROM error», 0011 read and 0012 write; if it repeats with the same operation, it is a hardware fault. Loss of absolute position is Z70 (ch. 6).

More alarms for Mitsubishi

See all alarms for this brand

Related apps