Example at Ø25 mm
Hole H7 from 0 to +21 µm and shaft h6 from -13 to 0 µm, which gives a clearance between 0 and 34 µm.
Visual, interactive ISO 286 tolerance calculator to view min/max limits, clearance, transition and interference on shaft and hole fits such as H7/g6, H7/h6, H7/k6 or H7/p6.
Hole
H7
Shaft
h6
H7/h6 · Ø50
With clearance: clearance of 0 to 41 µm
(0.000 … 0.041 mm)
Tolerances visually exaggerated to make the type of fit clear.
Actual hole
50.000 a 50.025 mm
Tolerancia: 0.000 a 0.025 mm
Actual shaft
49.984 a 50.000 mm
Tolerancia: -0.016 a 0.000 mm
Holgura/apriete
0.000 a 0.041 mm
Difference between the allowed hole and the allowed shaft.
Preset H7/h6
Hand assembly with a very close or line-to-line fit.
How to interpret it
There is always clearance: the shaft goes in without forcing. Suited to parts that rotate or slide.
Each pair comes out with real sizes within its tolerance, as in the shop. Clearances are exaggerated so you can see them.
Drag the shaft towards the bore.
Clearance/location. Hand assembly with a very close or line-to-line fit.
Hole H7 from 0 to +21 µm and shaft h6 from -13 to 0 µm, which gives a clearance between 0 and 34 µm.
The H7 hole (IT7) by reaming, fine boring or internal grinding; the h6 shaft (IT6) by grinding or fine turning on a machine in good condition. Check both with a plug gauge and a micrometer, not with a caliper.
By hand, with no force; the parts slide or turn freely.
| Ø range (mm) | Hole H7 | Shaft h6 | Clearance min … max | Interference ← → clearance (µm) |
|---|---|---|---|---|
| 1–3 | 0 / +10 | -6 / 0 | 0 … +16 | |
| 3–6 | 0 / +12 | -8 / 0 | 0 … +20 | |
| 6–10 | 0 / +15 | -9 / 0 | 0 … +24 | |
| 10–18 | 0 / +18 | -11 / 0 | 0 … +29 | |
| 18–30 | 0 / +21 | -13 / 0 | 0 … +34 | |
| 30–50← Ø50 | 0 / +25 | -16 / 0 | 0 … +41 | |
| 50–80 | 0 / +30 | -19 / 0 | 0 … +49 | |
| 80–120 | 0 / +35 | -22 / 0 | 0 … +57 | |
| 120–180 | 0 / +40 | -25 / 0 | 0 … +65 | |
| 180–250 | 0 / +46 | -29 / 0 | 0 … +75 | |
| 250–315 | 0 / +52 | -32 / 0 | 0 … +84 | |
| 315–400 | 0 / +57 | -36 / 0 | 0 … +93 | |
| 400–500 | 0 / +63 | -40 / 0 | 0 … +103 |
First the IT tolerance is obtained and then it is positioned according to the letter.
i = 0,45 · ∛D + 0,001 · D
`D` is the mean diameter of the nominal range. The multiplier is then applied: IT6 = 10i, IT7 = 16i, IT8 = 25i, IT9 = 40i.
H7, K11, g6, p6...
The letter places the area with respect to the nominal. Uppercase for hole (`ES/EI`) and lowercase for axis (`es/ei`).
holgura = agujero - eje
If the minimum clearance is positive, it is a clearance fit. If the maximum is negative, it is an interference fit. If it crosses zero, it is a transition fit.
IT grades and fundamental deviations up to 500 mm use the technical values published in handbooks and catalogues; the formula is only used where the standard does not define that position. For critical production, always check against the official ISO 286 and the controlled drawing.
From the loosest to the tightest. Open the fit you need to see the hole and shaft deviations, the resulting clearance or interference and how to assemble it. Clearance or interference calculated for Ø50 mm.
Look up the meaning of every drawing symbol: GD&T geometric tolerances (flatness, position, concentricity...), ISO 10135 casting, heat treatment, inspection and welding, with practical shop-floor explanations.
Works out ΔL with α corrected for the temperature you work at, corrects a reading to 20 °C using the part and the instrument you measured with, tells you how far to heat the bore or chill the shaft to fit, and how long to wait before measuring.
Upload a plan, extract dimensions and GD&T with AI and export your inspection guideline in PDF or CSV.
We use technical and security cookies and, only if you accept, analytics with no cross-site tracking. More in the Cookie policy and Privacy policy.
We use first-party cookies and technical storage to make the site work, Google reCAPTCHA security technology and, only if you accept, Vercel analytics (no cookies, no cross-site tracking). You can accept or reject analytics; both options are equivalent and you can change your choice at any time. More info: Cookie policy, Privacy policy, Legal notice and Terms and conditions.