Okuma 3030/8618 alarm: Spindle alarm/overload
Okuma detects an overload of the live tool spindle (8618 «M spindle overload» on OSP-P300 lathes) or of its drive.
For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.
The brands and control names mentioned belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, ISO or ASME: this is our own content, not official documentation. Legal notice.
- Control
- Okuma
- Machine
- Milling, Turning, Mill-turn
- Area
- Spindle
- Severity
- Critical
Symptoms
- Spindle stops.
- High load.
- Fails when starting or cutting.
Common causes
- Worn tool.
- Excessive load.
- Spindle drive.
- Motor/cooling.
First safe checks
- 01Check load, tool and RPM.
- 02Test with no load if it is safe.
- 03Write down the drive alarm.
What not to do
- Do not bypass safety devices.
- Do not manipulate energized electrical cabinet.
- Do not continue producing if the alarm reappears.
When to call maintenance:
If it appears with no load or there is a drive fault.
Reset/rearm:
Reset with the spindle stopped, after removing the cause of the load.
Okuma OSP-P300S/P300L Alarm & Error List (5921-E), Alarm A, p. 244: 8618 «M spindle overload» (live tool spindle; title in the index). In the Okuma OSP-E100M Alarm & Error List (4293-E-R2), 3030 is «SVP SA regenerative resistor overheat» (Alarm C), not a spindle overload.
Sources
- Official manual: Okuma OSP-P300S/P300L Alarm & Error List (5921-E) · p. 244
- Official manual: Okuma OSP-E100M Alarm & Error List (4293-E-R2)
Official documentation
Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.
Brand and control names belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, and this guide is not official documentation.
Frequently asked questions
What does alarm Okuma 3030/8618 mean on Okuma?
Okuma detects an overload of the live tool spindle (8618 «M spindle overload» on OSP-P300 lathes) or of its drive. It is an alarm from the Spindle area, and in the catalog it is listed as “Spindle alarm/overload”. On the machine you notice it like this: Spindle stops, High load, Fails when starting or cutting.
Why does alarm Okuma 3030/8618 come up?
On the shop floor it almost always comes from one of these causes: Worn tool, Excessive load, Spindle drive, Motor/cooling. Rule out the most likely one on your machine first, before touching parameters or swapping anything.
How do you clear alarm Okuma 3030/8618?
Reset with the spindle stopped, after removing the cause of the load. Resetting without fixing the cause first only hides the problem: Okuma 3030/8618 trips again and, in the meantime, you keep working with the machine in bad shape.
What should I check first with alarm Okuma 3030/8618?
With the machine stopped and in a safe state, start with these checks: Check load, tool and RPM, Test with no load if it is safe, Write down the drive alarm. That alone will tell you whether it is the program or whether you need to raise a maintenance job.
What should I NOT do with alarm Okuma 3030/8618?
With Okuma 3030/8618 active, avoid this: Do not bypass safety devices, Do not manipulate energized electrical cabinet, Do not continue producing if the alarm reappears. Skipping any of these points is what turns a minor stop into an expensive breakdown.
When do I have to call maintenance for alarm Okuma 3030/8618?
If it appears with no load or there is a drive fault. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.
How serious is alarm Okuma 3030/8618?
It is critical: there is a real risk of damage to the machine, the tool or a person. Leave the machine stopped, do not keep resetting it to see if it goes away, and call maintenance before producing again. Okuma OSP-P300S/P300L Alarm & Error List (5921-E), Alarm A, p. 244: 8618 «M spindle overload» (live tool spindle; title in the index). In the Okuma OSP-E100M Alarm & Error List (4293-E-R2), 3030 is «SVP SA regenerative resistor overheat» (Alarm C), not a spindle overload.
More alarms for Okuma
Related apps
GSM Code List
List of G and M Codes for CNC Programming. Search and filter ISO commands by control, machine or function.
CNC G-code Simulator
CNC IDE: editing with G/M tooltips, line inspector, conversion between controls and 2D/3D toolpath.
Calculate cycle time
Estimate CNC turning and milling cycle time from G-code. Calculate parts per hour with a breakdown of cutting, rapids, canned cycles and tool changes.