Back to CNC Alarms Guide

Okuma 4806/4807 alarm: Lubrication problem/low level

Okuma warns of a lubrication tank or low oil level in axles.

For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.

Control
Okuma
Machine
Milling, Turning, Mill-turn
Area
Lubrication
Severity
Critical

Symptoms

  • Warning or stop due to lubrication.
  • Risk for guides/axles.
  • It can be repeated periodically.

Common causes

  • Nivel bajo.
  • Tanque de drenaje lleno.
  • Pump or sensor.
  • Blocked line.

First safe checks

  1. 01Comprobar niveles.
  2. 02Revisar fugas.
  3. 03Do not produce without confirmed lubrication.

What not to do

  • Do not bypass safety devices.
  • Do not manipulate energized electrical cabinet.
  • Do not continue producing if the alarm reappears.

When to call maintenance:

If level/pressure is not recovered or there is a leak.

Reset/rearm:

Reset after reestablishing lubrication system.

Official documentation

Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.

Frequently Asked Questions (FAQ)

What does alarm Okuma 4806/4807 mean on Okuma?

Okuma warns of a lubrication tank or low oil level in axles. It is an alarm from the Lubrication area, and in the catalog it is listed as “Lubrication problem/low level”. On the machine you notice it like this: Warning or stop due to lubrication, Risk for guides/axles, It can be repeated periodically.

Why does alarm Okuma 4806/4807 come up?

On the shop floor it almost always comes from one of these causes: Nivel bajo, Tanque de drenaje lleno, Pump or sensor, Blocked line. Rule out the most likely one on your machine first, before touching parameters or swapping anything.

How do you clear alarm Okuma 4806/4807?

Reset after reestablishing lubrication system. Resetting without fixing the cause first only hides the problem: Okuma 4806/4807 trips again and, in the meantime, you keep working with the machine in bad shape.

What should I check first with alarm Okuma 4806/4807?

With the machine stopped and in a safe state, start with these checks: Comprobar niveles, Revisar fugas, Do not produce without confirmed lubrication. That alone will tell you whether it is the program or whether you need to raise a maintenance job.

What should I NOT do with alarm Okuma 4806/4807?

With Okuma 4806/4807 active, avoid this: Do not bypass safety devices, Do not manipulate energized electrical cabinet, Do not continue producing if the alarm reappears. Skipping any of these points is what turns a minor stop into an expensive breakdown.

When do I have to call maintenance for alarm Okuma 4806/4807?

If level/pressure is not recovered or there is a leak. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.

How serious is alarm Okuma 4806/4807?

It is critical: there is a real risk of damage to the machine, the tool or a person. Leave the machine stopped, do not keep resetting it to see if it goes away, and call maintenance before producing again. Guidance reference. Always confirm the full text in the exact machine/control manual.