Siemens 10700/10701 alarm: Protection zone violated
Sinumerik detects that the path enters an NCK or channel-specific protection zone.
For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.
- Control
- Siemens
- Machine
- Milling, Turning, Mill-turn
- Area
- Safety
- Severity
- Stop
Symptoms
- Alarm in automatic/MDA.
- Trayectoria bloqueada.
- May involve a fixture, chuck or protected zone.
Common causes
- Poorly defined active protection.
- Incorrect origin/tool.
- Program crosses prohibited zone.
- Kinematics/transformation.
First safe checks
- 01Check protection zone.
- 02Check tool and offset.
- 03Simular trayectoria.
What not to do
- Do not bypass safety devices.
- Do not manipulate energized electrical cabinet.
- Do not continue producing if the alarm reappears.
When to call maintenance:
If the protected zone was modified or its origin is unclear.
Reset/rearm:
Reset after correcting path or authorized configuration.
Official documentation
Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.
Frequently Asked Questions (FAQ)
What does alarm Siemens 10700/10701 mean on Siemens?
Sinumerik detects that the path enters an NCK or channel-specific protection zone. It is an alarm from the Safety area, and in the catalog it is listed as “Protection zone violated”. On the machine you notice it like this: Alarm in automatic/MDA, Trayectoria bloqueada, May involve a fixture, chuck or protected zone.
Why does alarm Siemens 10700/10701 come up?
On the shop floor it almost always comes from one of these causes: Poorly defined active protection, Incorrect origin/tool, Program crosses prohibited zone, Kinematics/transformation. Rule out the most likely one on your machine first, before touching parameters or swapping anything.
How do you clear alarm Siemens 10700/10701?
Reset after correcting path or authorized configuration. Resetting without fixing the cause first only hides the problem: Siemens 10700/10701 trips again and, in the meantime, you keep working with the machine in bad shape.
What should I check first with alarm Siemens 10700/10701?
With the machine stopped and in a safe state, start with these checks: Check protection zone, Check tool and offset, Simular trayectoria. That alone will tell you whether it is the program or whether you need to raise a maintenance job.
What should I NOT do with alarm Siemens 10700/10701?
With Siemens 10700/10701 active, avoid this: Do not bypass safety devices, Do not manipulate energized electrical cabinet, Do not continue producing if the alarm reappears. Skipping any of these points is what turns a minor stop into an expensive breakdown.
When do I have to call maintenance for alarm Siemens 10700/10701?
If the protected zone was modified or its origin is unclear. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.
How serious is alarm Siemens 10700/10701?
It is a stop alarm: the cycle will not continue until you fix the cause. It does not always mean serious damage, but it leaves the machine where it is and you have to check it before running again. Guidance reference. Always confirm the full text in the exact machine/control manual.
More alarms for Siemens
Related tools
GSM Code List
List of G and M Codes for CNC Programming. Search and filter ISO commands by control, machine or function.
CNC G-code Simulator
CNC IDE: editing with G/M tooltips, line inspector, conversion between controls and 2D/3D toolpath.
Calculate cycle time
Estimate CNC turning and milling cycle time from G-code. Calculate parts per hour with a breakdown of cutting, rapids, canned cycles and tool changes.