Siemens 2000/20000 alarm: PLC sign-of-life / PLC not started

Sinumerik does not receive correct life signal from the PLC or the PLC has not started.

For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.

The brands and control names mentioned belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, ISO or ASME: this is our own content, not official documentation. Legal notice.

Control
Siemens
Machine
Milling, Turning, Mill-turn
Area
PLC/machine
Severity
Critical

Symptoms

  • The machine is not ready.
  • PLC alarms at start-up.
  • HMI/NC waits for machine signals.

Common causes

  • PLC stopped.
  • PLC program or communication.
  • I/O module.
  • Incomplete start after electrical failure.

First safe checks

  1. 01Write down the full NC/PLC alarms.
  2. 02Review PLC diagnosis.
  3. 03Reboot following OEM procedure.

What not to do

  • Do not bypass safety devices.
  • Do not manipulate energized electrical cabinet.
  • Do not continue producing if the alarm reappears.

When to call maintenance:

If PLC does not start or there are module/I/O messages.

Reset/rearm:

Reset only after the PLC ready state is restored.

Confirmed for 2000 (PLC sign-of-life monitoring) and 2001 (PLC not started): 840D sl diagnostics manual 07/2021, p. 35. Note: 20000 is a different alarm, «reference cam not reached» (p. 396).

Sources

  • Official manual: SINUMERIK 840D sl / 828D Diagnostics Manual 07/2021 (6FC5398-6BP40-6BA5) · p. 35

Official documentation

Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.

Brand and control names belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, and this guide is not official documentation.

Frequently asked questions

What does alarm Siemens 2000/20000 mean on Siemens?

Sinumerik does not receive correct life signal from the PLC or the PLC has not started. It is an alarm from the PLC/machine area, and in the catalog it is listed as “PLC sign-of-life / PLC not started”. On the machine you notice it like this: The machine is not ready, PLC alarms at start-up, HMI/NC waits for machine signals.

Why does alarm Siemens 2000/20000 come up?

On the shop floor it almost always comes from one of these causes: PLC stopped, PLC program or communication, I/O module, Incomplete start after electrical failure. Rule out the most likely one on your machine first, before touching parameters or swapping anything.

How do you clear alarm Siemens 2000/20000?

Reset only after the PLC ready state is restored. Resetting without fixing the cause first only hides the problem: Siemens 2000/20000 trips again and, in the meantime, you keep working with the machine in bad shape.

What should I check first with alarm Siemens 2000/20000?

With the machine stopped and in a safe state, start with these checks: Write down the full NC/PLC alarms, Review PLC diagnosis, Reboot following OEM procedure. That alone will tell you whether it is the program or whether you need to raise a maintenance job.

What should I NOT do with alarm Siemens 2000/20000?

With Siemens 2000/20000 active, avoid this: Do not bypass safety devices, Do not manipulate energized electrical cabinet, Do not continue producing if the alarm reappears. Skipping any of these points is what turns a minor stop into an expensive breakdown.

When do I have to call maintenance for alarm Siemens 2000/20000?

If PLC does not start or there are module/I/O messages. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.

How serious is alarm Siemens 2000/20000?

It is critical: there is a real risk of damage to the machine, the tool or a person. Leave the machine stopped, do not keep resetting it to see if it goes away, and call maintenance before producing again. Confirmed for 2000 (PLC sign-of-life monitoring) and 2001 (PLC not started): 840D sl diagnostics manual 07/2021, p. 35. Note: 20000 is a different alarm, «reference cam not reached» (p. 396).