Siemens 2000/20000 alarm: PLC sign-of-life / PLC not started
Sinumerik does not receive correct life signal from the PLC or the PLC has not started.
For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.
- Control
- Siemens
- Machine
- Milling, Turning, Mill-turn
- Area
- PLC/machine
- Severity
- Critical
Symptoms
- The machine is not ready.
- PLC alarms at start-up.
- HMI/NC waits for machine signals.
Common causes
- PLC detenido.
- PLC program or communication.
- I/O module.
- Incomplete start after electrical failure.
First safe checks
- 01Anotar alarmas NC/PLC completas.
- 02Review PLC diagnosis.
- 03Reboot following OEM procedure.
What not to do
- Do not bypass safety devices.
- Do not manipulate energized electrical cabinet.
- Do not continue producing if the alarm reappears.
When to call maintenance:
If PLC does not start or there are module/I/O messages.
Reset/rearm:
Reset solo tras recuperar estado PLC listo.
Official documentation
Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.
Frequently Asked Questions (FAQ)
What does alarm Siemens 2000/20000 mean on Siemens?
Sinumerik does not receive correct life signal from the PLC or the PLC has not started. It is an alarm from the PLC/machine area, and in the catalog it is listed as “PLC sign-of-life / PLC not started”. On the machine you notice it like this: The machine is not ready, PLC alarms at start-up, HMI/NC waits for machine signals.
Why does alarm Siemens 2000/20000 come up?
On the shop floor it almost always comes from one of these causes: PLC detenido, PLC program or communication, I/O module, Incomplete start after electrical failure. Rule out the most likely one on your machine first, before touching parameters or swapping anything.
How do you clear alarm Siemens 2000/20000?
Reset solo tras recuperar estado PLC listo. Resetting without fixing the cause first only hides the problem: Siemens 2000/20000 trips again and, in the meantime, you keep working with the machine in bad shape.
What should I check first with alarm Siemens 2000/20000?
With the machine stopped and in a safe state, start with these checks: Anotar alarmas NC/PLC completas, Review PLC diagnosis, Reboot following OEM procedure. That alone will tell you whether it is the program or whether you need to raise a maintenance job.
What should I NOT do with alarm Siemens 2000/20000?
With Siemens 2000/20000 active, avoid this: Do not bypass safety devices, Do not manipulate energized electrical cabinet, Do not continue producing if the alarm reappears. Skipping any of these points is what turns a minor stop into an expensive breakdown.
When do I have to call maintenance for alarm Siemens 2000/20000?
If PLC does not start or there are module/I/O messages. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.
How serious is alarm Siemens 2000/20000?
It is critical: there is a real risk of damage to the machine, the tool or a person. Leave the machine stopped, do not keep resetting it to see if it goes away, and call maintenance before producing again. Guidance reference. Always confirm the full text in the exact machine/control manual.
More alarms for Siemens
Related tools
GSM Code List
List of G and M Codes for CNC Programming. Search and filter ISO commands by control, machine or function.
CNC G-code Simulator
CNC IDE: editing with G/M tooltips, line inspector, conversion between controls and 2D/3D toolpath.
Calculate cycle time
Estimate CNC turning and milling cycle time from G-code. Calculate parts per hour with a breakdown of cutting, rapids, canned cycles and tool changes.