Siemens 700xxx alarm: User Alarm/OEM PLC

Typical range of alarms generated by the machine manufacturer's PLC logic.

For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.

Control
Siemens
Machine
Milling, Turning, Mill-turn
Area
PLC/machine
Severity
Stop

Symptoms

  • Machine specific text.
  • It can refer to jaw, door, pressure, robot or peripheral.
  • The number alone is not enough.

Common causes

  • PLC input condition not met.
  • Secuencia incompleta.
  • Sensor or peripheral in incorrect condition.

First safe checks

  1. 01Leer texto completo.
  2. 02Go to PLC/I-O diagnostics.
  3. 03Verify indicated physical condition.

What not to do

  • Do not bypass safety devices.
  • Do not manipulate energized electrical cabinet.
  • Do not continue producing if the alarm reappears.

When to call maintenance:

If the signal is not identified or involves security/automatic peripherals.

Reset/rearm:

Reset after meeting the indicated PLC condition.

Official documentation

Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.

Frequently Asked Questions (FAQ)

What does alarm Siemens 700xxx mean on Siemens?

Typical range of alarms generated by the machine manufacturer's PLC logic. It is an alarm from the PLC/machine area, and in the catalog it is listed as “User Alarm/OEM PLC”. On the machine you notice it like this: Machine specific text, It can refer to jaw, door, pressure, robot or peripheral, The number alone is not enough.

Why does alarm Siemens 700xxx come up?

On the shop floor it almost always comes from one of these causes: PLC input condition not met, Secuencia incompleta, Sensor or peripheral in incorrect condition. Rule out the most likely one on your machine first, before touching parameters or swapping anything.

How do you clear alarm Siemens 700xxx?

Reset after meeting the indicated PLC condition. Resetting without fixing the cause first only hides the problem: Siemens 700xxx trips again and, in the meantime, you keep working with the machine in bad shape.

What should I check first with alarm Siemens 700xxx?

With the machine stopped and in a safe state, start with these checks: Leer texto completo, Go to PLC/I-O diagnostics, Verify indicated physical condition. That alone will tell you whether it is the program or whether you need to raise a maintenance job.

What should I NOT do with alarm Siemens 700xxx?

With Siemens 700xxx active, avoid this: Do not bypass safety devices, Do not manipulate energized electrical cabinet, Do not continue producing if the alarm reappears. Skipping any of these points is what turns a minor stop into an expensive breakdown.

When do I have to call maintenance for alarm Siemens 700xxx?

If the signal is not identified or involves security/automatic peripherals. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.

How serious is alarm Siemens 700xxx?

It is a stop alarm: the cycle will not continue until you fix the cause. It does not always mean serious damage, but it leaves the machine where it is and you have to check it before running again. Guidance reference. Always confirm the full text in the exact machine/control manual.