Haas 101 alarm: Communication failure with Mocon

The Haas control detects communication or memory failure with the board/motion control.

For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.

The brands and control names mentioned belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, ISO or ASME: this is our own content, not official documentation. Legal notice.

Control
Haas
Machine
Milling, Turning, Mill-turn
Area
PLC/machine
Severity
Critical

Symptoms

  • Alarm when turned on.
  • The servos may not enable.
  • The machine is not ready.

Common causes

  • Mocon/motion control board.
  • Internal connection.
  • Memory or board power.
  • Electronic failure.

First safe checks

  1. 01Write down the startup alarms.
  2. 02Restart following normal procedure.
  3. 03Check if there are other power alarms.

What not to do

  • Do not bypass safety devices.
  • Do not manipulate energized electrical cabinet.
  • Do not continue producing if the alarm reappears.

When to call maintenance:

If it persists after a normal restart.

Reset/rearm:

It is not usually resolved with reset if it is internal communication; requires diagnosis.

Confirmed only in a secondary source: 101 MOCON COMM. FAILURE in a copy of the Haas service manual 96-0284 (classic control). It is a classic control alarm, predating the NGC.

Sources

  • Secondary source: Haas Service Manual 96-0284 (control clásico, copia no oficial) · 101 MOCON COMM. FAILURE

Official documentation

Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.

Brand and control names belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, and this guide is not official documentation.

Frequently asked questions

What does alarm Haas 101 mean on Haas?

The Haas control detects communication or memory failure with the board/motion control. It is an alarm from the PLC/machine area, and in the catalog it is listed as “Communication failure with Mocon”. On the machine you notice it like this: Alarm when turned on, The servos may not enable, The machine is not ready.

Why does alarm Haas 101 come up?

On the shop floor it almost always comes from one of these causes: Mocon/motion control board, Internal connection, Memory or board power, Electronic failure. Rule out the most likely one on your machine first, before touching parameters or swapping anything.

How do you clear alarm Haas 101?

It is not usually resolved with reset if it is internal communication; requires diagnosis. Resetting without fixing the cause first only hides the problem: Haas 101 trips again and, in the meantime, you keep working with the machine in bad shape.

What should I check first with alarm Haas 101?

With the machine stopped and in a safe state, start with these checks: Write down the startup alarms, Restart following normal procedure, Check if there are other power alarms. That alone will tell you whether it is the program or whether you need to raise a maintenance job.

What should I NOT do with alarm Haas 101?

With Haas 101 active, avoid this: Do not bypass safety devices, Do not manipulate energized electrical cabinet, Do not continue producing if the alarm reappears. Skipping any of these points is what turns a minor stop into an expensive breakdown.

When do I have to call maintenance for alarm Haas 101?

If it persists after a normal restart. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.

How serious is alarm Haas 101?

It is critical: there is a real risk of damage to the machine, the tool or a person. Leave the machine stopped, do not keep resetting it to see if it goes away, and call maintenance before producing again. Confirmed only in a secondary source: 101 MOCON COMM. FAILURE in a copy of the Haas service manual 96-0284 (classic control). It is a classic control alarm, predating the NGC.