Haas 552 alarm: Tripped circuit breaker
On the NGC control a circuit breaker on the power distribution board has tripped: coolant pump, conveyor, TSC pump or work light.
For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.
The brands and control names mentioned belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, ISO or ASME: this is our own content, not official documentation. Legal notice.
- Control
- Haas
- Machine
- Milling, Turning, Mill-turn
- Area
- Power supply
- Severity
- Stop
Symptoms
- The coolant pump, chip conveyor, TSC pump or work light stops.
- The alarm won't clear with RESET while the circuit breaker is still tripped.
Common causes
- Coolant or TSC pump jammed.
- Chip conveyor jammed by chips or a part.
- Damaged cable or shorted motor.
First safe checks
- 01Write down which unit has stopped.
- 02With the machine stopped, look for jams in the pump or the conveyor.
- 03Check the cable of the affected unit for cuts or chafing.
What not to do
- Do not keep resetting the circuit breaker without looking for the cause.
- Don't open the electrical cabinet without qualification.
When to call maintenance:
If it trips again right after resetting it, if the motor smells burnt or if there is no visible jam.
Reset/rearm:
Fix the cause, reset the circuit breaker on the distribution board and then clear the alarms.
Confirmed in the official Haas NGC alarm search (552 TRIPPED CIRCUIT BREAKER): CB3 coolant pump, CB4 conveyor, CB5 TSC pump, CB6 work light. On the NGC, 552 is not a door alarm.
Sources
- Manufacturer's official website: Haas Alarm Search (NGC) · 552 TRIPPED CIRCUIT BREAKER
Official documentation
Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.
Brand and control names belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, and this guide is not official documentation.
Frequently asked questions
What does alarm Haas 552 mean on Haas?
On the NGC control a circuit breaker on the power distribution board has tripped: coolant pump, conveyor, TSC pump or work light. It is an alarm from the Power supply area, and in the catalog it is listed as “Tripped circuit breaker”. On the machine you notice it like this: The coolant pump, chip conveyor, TSC pump or work light stops, The alarm won't clear with RESET while the circuit breaker is still tripped.
Why does alarm Haas 552 come up?
On the shop floor it almost always comes from one of these causes: Coolant or TSC pump jammed, Chip conveyor jammed by chips or a part, Damaged cable or shorted motor. Rule out the most likely one on your machine first, before touching parameters or swapping anything.
How do you clear alarm Haas 552?
Fix the cause, reset the circuit breaker on the distribution board and then clear the alarms. Resetting without fixing the cause first only hides the problem: Haas 552 trips again and, in the meantime, you keep working with the machine in bad shape.
What should I check first with alarm Haas 552?
With the machine stopped and in a safe state, start with these checks: Write down which unit has stopped, With the machine stopped, look for jams in the pump or the conveyor, Check the cable of the affected unit for cuts or chafing. That alone will tell you whether it is the program or whether you need to raise a maintenance job.
What should I NOT do with alarm Haas 552?
With Haas 552 active, avoid this: Do not keep resetting the circuit breaker without looking for the cause, Don't open the electrical cabinet without qualification. Skipping any of these points is what turns a minor stop into an expensive breakdown.
When do I have to call maintenance for alarm Haas 552?
If it trips again right after resetting it, if the motor smells burnt or if there is no visible jam. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.
How serious is alarm Haas 552?
It is a stop alarm: the cycle will not continue until you fix the cause. It does not always mean serious damage, but it leaves the machine where it is and you have to check it before running again. Confirmed in the official Haas NGC alarm search (552 TRIPPED CIRCUIT BREAKER): CB3 coolant pump, CB4 conveyor, CB5 TSC pump, CB6 work light. On the NGC, 552 is not a door alarm.
More alarms for Haas
Related apps
GSM Code List
List of G and M Codes for CNC Programming. Search and filter ISO commands by control, machine or function.
CNC G-code Simulator
CNC IDE: editing with G/M tooltips, line inspector, conversion between controls and 2D/3D toolpath.
Calculate cycle time
Estimate CNC turning and milling cycle time from G-code. Calculate parts per hour with a breakdown of cutting, rapids, canned cycles and tool changes.