Haas 160 alarm: Low voltage

Haas detects power below the required range.

For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.

The brands and control names mentioned belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, ISO or ASME: this is our own content, not official documentation. Legal notice.

Control
Haas
Machine
Milling, Turning, Mill-turn
Area
Power supply
Severity
Critical

Symptoms

  • Alarm when starting or during acceleration.
  • Servos/spindle get disabled.
  • It may coincide with a network outage.

Common causes

  • Low input voltage.
  • Transformer/taps set up incorrectly.
  • Loose connection.
  • External electrical load.

First safe checks

  1. 01Measure voltage by qualified personnel.
  2. 02Note when it occurs.
  3. 03Check the power failure history.

What not to do

  • Do not bypass safety devices.
  • Do not manipulate energized electrical cabinet.
  • Do not continue producing if the alarm reappears.

When to call maintenance:

Always if it persists or affects machine power.

Reset/rearm:

Reset only after confirming correct voltage.

Confirmed in the official Haas NGC alarm search: 160 LOW INCOMING AC LINE VOLTAGE (incoming line voltage low). DC bus voltage drop is 649 DC BUS UNDER VOLTAGE.

Sources

Official documentation

Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.

Brand and control names belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, and this guide is not official documentation.

Frequently asked questions

What does alarm Haas 160 mean on Haas?

Haas detects power below the required range. It is an alarm from the Power supply area, and in the catalog it is listed as “Low voltage”. On the machine you notice it like this: Alarm when starting or during acceleration, Servos/spindle get disabled, It may coincide with a network outage.

Why does alarm Haas 160 come up?

On the shop floor it almost always comes from one of these causes: Low input voltage, Transformer/taps set up incorrectly, Loose connection, External electrical load. Rule out the most likely one on your machine first, before touching parameters or swapping anything.

How do you clear alarm Haas 160?

Reset only after confirming correct voltage. Resetting without fixing the cause first only hides the problem: Haas 160 trips again and, in the meantime, you keep working with the machine in bad shape.

What should I check first with alarm Haas 160?

With the machine stopped and in a safe state, start with these checks: Measure voltage by qualified personnel, Note when it occurs, Check the power failure history. That alone will tell you whether it is the program or whether you need to raise a maintenance job.

What should I NOT do with alarm Haas 160?

With Haas 160 active, avoid this: Do not bypass safety devices, Do not manipulate energized electrical cabinet, Do not continue producing if the alarm reappears. Skipping any of these points is what turns a minor stop into an expensive breakdown.

When do I have to call maintenance for alarm Haas 160?

Always if it persists or affects machine power. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.

How serious is alarm Haas 160?

It is critical: there is a real risk of damage to the machine, the tool or a person. Leave the machine stopped, do not keep resetting it to see if it goes away, and call maintenance before producing again. Confirmed in the official Haas NGC alarm search: 160 LOW INCOMING AC LINE VOLTAGE (incoming line voltage low). DC bus voltage drop is 649 DC BUS UNDER VOLTAGE.

More alarms for Haas

See all alarms for this brand

Related apps