Pressure looks normal at idle, but the alarm occurs during a tool change.
Check the supply condition under that demand using the machine procedure. The idle reading alone cannot exclude a restriction, insufficient delivery or leakage.
We use technical and security cookies and, only if you accept, analytics with no cross-site tracking. More in the Cookie policy and Privacy policy.
We use first-party cookies and technical storage to make the site work, Google reCAPTCHA security technology and, only if you accept, Vercel analytics (no cookies, no cross-site tracking). You can accept or reject analytics; both options are equivalent and you can change your choice at any time. More info: Cookie policy, Privacy policy, Legal notice and Terms and conditions.
Haas identifies alarm 120 as low air pressure or flow. Check the machine’s air supply against its own requirements, including what happens while pneumatic functions operate; a satisfactory idle reading does not establish adequate supply under demand.
For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.
If there are large leaks, sensor does not change or pressure drops during cycle.
Restore correct pressure and reset.
Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.
A pneumatic supply must provide the required conditions when the machine consumes air. Pressure and flow are related, but a pressure reading taken with everything stationary does not describe the whole operating cycle. Use the complete Haas message and the machine’s stated air requirements to direct checks. Record whether the alarm occurs at startup, during a tool change or when another air-consuming function runs. These observations help service distinguish an upstream supply problem from a machine-side problem without guessing a universal pressure setting.
In order, from the fastest and cheapest check to the most expensive.
01Record the message and operating condition
Save the complete alarm and the operation in progress. Note whether other machines or air consumers were running at the same time. Keep this context with the pressure reading rather than recording an isolated number.
02Compare with the machine requirement
Locate the specified air supply conditions for the installed model. Read the accessible gauge and check the normal supply status. Do not increase a regulator beyond the documented requirement simply to clear the alarm.
03Observe supply during permitted operation
Where the normal procedure allows it, record whether pressure drops as the affected function operates. Keep doors and safeguards in their required state. A drop during demand is useful information for checking supply capacity, restrictions or leaks.
04Escalate persistent faults with evidence
Provide service with the readings, timing and supply information. If the indicated pressure seems correct but the alarm persists, leave sensor and electrical checks to authorised personnel. Do not bypass a pressure input to continue production.
Check the supply condition under that demand using the machine procedure. The idle reading alone cannot exclude a restriction, insufficient delivery or leakage.
Record the coincidence and ask the responsible team to assess the shared supply. Do not compensate by changing machine settings without confirming the required conditions.
Maintain the air supply according to the machine and workshop requirements. Record recurring pressure drops and address them before repeated production interruptions. Keep filters, supply connections and leak checks within the maintenance plan appropriate to the equipment.
The Haas machine does not detect sufficient air pressure to operate systems. It is an alarm from the Safety area, and in the catalog it is listed as “Low air pressure”. On the machine you notice it like this: Does not allow tool or cycle change, Alarm when starting, Pneumatic actuators do not complete.
On the shop floor it almost always comes from one of these causes: Compressor without pressure, Regulator setting too low, Air leak, Defective pressure sensor. Rule out the most likely one on your machine first, before touching parameters or swapping anything.
Restore correct pressure and reset. Resetting without fixing the cause first only hides the problem: Haas 120 trips again and, in the meantime, you keep working with the machine in bad shape.
With the machine stopped and in a safe state, start with these checks: Check pressure gauge, Check for audible air leaks, Confirm minimum pressure indicated by machine. That alone will tell you whether it is the program or whether you need to raise a maintenance job.
With Haas 120 active, avoid this: Do not bypass safety devices, Do not manipulate energized electrical cabinet, Do not continue producing if the alarm reappears. Skipping any of these points is what turns a minor stop into an expensive breakdown.
If there are large leaks, sensor does not change or pressure drops during cycle. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.
It is a stop alarm: the cycle will not continue until you fix the cause. It does not always mean serious damage, but it leaves the machine where it is and you have to check it before running again. Guidance reference. Always confirm the full text in the exact machine/control manual.
List of G and M Codes for CNC Programming. Search and filter ISO commands by control, machine or function.
CNC IDE: editing with G/M tooltips, line inspector, conversion between controls and 2D/3D toolpath.
Estimate CNC turning and milling cycle time from G-code. Calculate parts per hour with a breakdown of cutting, rapids, canned cycles and tool changes.