Siemens 10720 alarm: Software limit switch

Sinumerik detects a move in the program that would end beyond an axis's active software limit switch.

For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.

The brands and control names mentioned belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, ISO or ASME: this is our own content, not official documentation. Legal notice.

Control
Siemens
Machine
Milling, Turning, Mill-turn
Area
Sobrecarrera
Severity
Stop

Symptoms

  • The alarm shows channel, block, axis and direction (+ or -).
  • The program stops before executing the move.
  • It offers to correct the block.

Common causes

  • Programmed dimension outside the travel.
  • Wrong work offset or tool offset.
  • 2nd software limit switch activated by the PLC.
  • Program made for another machine or fixture.

First safe checks

  1. 01Write down axis, direction and block.
  2. 02Check the active work offset and the tool offset.
  3. 03Simulate the program and check the axis position in that block.

What not to do

  • Do not modify the soft limits to get it through.
  • Do not jog the axis by hand toward the limit to test it.

When to call maintenance:

If the coordinate is correct and the limit seems wrongly set or the 2nd limit switch is active for no reason.

Reset/rearm:

Correct the block or the work offset and clear with RESET before starting again.

Confirmed: SINUMERIK 840D sl, diagnostics manual 07/2021 (6FC5398-6BP40-6BA5), p. 134, and 840D Diagnostics Manual 11/2002, alarm 10720 «Axis software limit switch».

Sources

  • Official manual: SINUMERIK 840D sl / 828D Diagnostics Manual 07/2021 (6FC5398-6BP40-6BA5) · p. 134
  • Official manual: SINUMERIK 840D/840Di/810D Instrucciones de diagnosis, edición 11/2002

Official documentation

Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.

Brand and control names belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, and this guide is not official documentation.

Frequently asked questions

What does alarm Siemens 10720 mean on Siemens?

Sinumerik detects a move in the program that would end beyond an axis's active software limit switch. It is an alarm from the Sobrecarrera area, and in the catalog it is listed as “Software limit switch”. On the machine you notice it like this: The alarm shows channel, block, axis and direction (+ or -), The program stops before executing the move, It offers to correct the block.

Why does alarm Siemens 10720 come up?

On the shop floor it almost always comes from one of these causes: Programmed dimension outside the travel, Wrong work offset or tool offset, 2nd software limit switch activated by the PLC, Program made for another machine or fixture. Rule out the most likely one on your machine first, before touching parameters or swapping anything.

How do you clear alarm Siemens 10720?

Correct the block or the work offset and clear with RESET before starting again. Resetting without fixing the cause first only hides the problem: Siemens 10720 trips again and, in the meantime, you keep working with the machine in bad shape.

What should I check first with alarm Siemens 10720?

With the machine stopped and in a safe state, start with these checks: Write down axis, direction and block, Check the active work offset and the tool offset, Simulate the program and check the axis position in that block. That alone will tell you whether it is the program or whether you need to raise a maintenance job.

What should I NOT do with alarm Siemens 10720?

With Siemens 10720 active, avoid this: Do not modify the soft limits to get it through, Do not jog the axis by hand toward the limit to test it. Skipping any of these points is what turns a minor stop into an expensive breakdown.

When do I have to call maintenance for alarm Siemens 10720?

If the coordinate is correct and the limit seems wrongly set or the 2nd limit switch is active for no reason. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.

How serious is alarm Siemens 10720?

It is a stop alarm: the cycle will not continue until you fix the cause. It does not always mean serious damage, but it leaves the machine where it is and you have to check it before running again. Confirmed: SINUMERIK 840D sl, diagnostics manual 07/2021 (6FC5398-6BP40-6BA5), p. 134, and 840D Diagnostics Manual 11/2002, alarm 10720 «Axis software limit switch».