Siemens 380500/400000 alarm: PROFIBUS/PLC status fault
Sinumerik detects PROFIBUS bus/drive failure or PLC out of cyclic mode.
For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.
- Control
- Siemens
- Machine
- Milling, Turning, Mill-turn
- Area
- PLC/machine
- Severity
- Critical
Symptoms
- Machine is not ready.
- I/O modules or drives do not communicate.
- PLC detenido.
Common causes
- Cable/bus PROFIBUS.
- I/O module.
- PLC not in RUN.
- Drive or node without power.
First safe checks
- 01Write down subcodes.
- 02Revisar LEDs de bus/nodos.
- 03Do not change configuration without backup.
What not to do
- Do not bypass safety devices.
- Do not manipulate energized electrical cabinet.
- Do not continue producing if the alarm reappears.
When to call maintenance:
Always, if it affects the bus, a drive or the PLC.
Reset/rearm:
Reset after reestablishing communication and PLC RUN.
Official documentation
Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.
Frequently Asked Questions (FAQ)
What does alarm Siemens 380500/400000 mean on Siemens?
Sinumerik detects PROFIBUS bus/drive failure or PLC out of cyclic mode. It is an alarm from the PLC/machine area, and in the catalog it is listed as “PROFIBUS/PLC status fault”. On the machine you notice it like this: Machine is not ready, I/O modules or drives do not communicate, PLC detenido.
Why does alarm Siemens 380500/400000 come up?
On the shop floor it almost always comes from one of these causes: Cable/bus PROFIBUS, I/O module, PLC not in RUN, Drive or node without power. Rule out the most likely one on your machine first, before touching parameters or swapping anything.
How do you clear alarm Siemens 380500/400000?
Reset after reestablishing communication and PLC RUN. Resetting without fixing the cause first only hides the problem: Siemens 380500/400000 trips again and, in the meantime, you keep working with the machine in bad shape.
What should I check first with alarm Siemens 380500/400000?
With the machine stopped and in a safe state, start with these checks: Write down subcodes, Revisar LEDs de bus/nodos, Do not change configuration without backup. That alone will tell you whether it is the program or whether you need to raise a maintenance job.
What should I NOT do with alarm Siemens 380500/400000?
With Siemens 380500/400000 active, avoid this: Do not bypass safety devices, Do not manipulate energized electrical cabinet, Do not continue producing if the alarm reappears. Skipping any of these points is what turns a minor stop into an expensive breakdown.
When do I have to call maintenance for alarm Siemens 380500/400000?
Always, if it affects the bus, a drive or the PLC. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.
How serious is alarm Siemens 380500/400000?
It is critical: there is a real risk of damage to the machine, the tool or a person. Leave the machine stopped, do not keep resetting it to see if it goes away, and call maintenance before producing again. Guidance reference. Always confirm the full text in the exact machine/control manual.
More alarms for Siemens
Related tools
GSM Code List
List of G and M Codes for CNC Programming. Search and filter ISO commands by control, machine or function.
CNC G-code Simulator
CNC IDE: editing with G/M tooltips, line inspector, conversion between controls and 2D/3D toolpath.
Calculate cycle time
Estimate CNC turning and milling cycle time from G-code. Calculate parts per hour with a breakdown of cutting, rapids, canned cycles and tool changes.