Skip to content

Siemens 61015 alarm: Cycle: contour not defined

The Siemens cycle cannot find the referenced contour to machine.

For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.

The brands and control names mentioned belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, ISO or ASME: this is our own content, not official documentation. Legal notice.

Control
Siemens
Machine
Milling, Turning
Area
Program
Severity
Stop

Symptoms

  • Fails when running the contour cycle.
  • Cycle block message.
  • Common after editing/renaming contours.

Common causes

  • Contour deleted or renamed.
  • Badly defined labels.
  • Inconsistent post.

First safe checks

  1. 01Check the contour name/labels.
  2. 02Validate geometry in simulation.
  3. 03Check the post processor.

What not to do

  • Do not delete blocks you do not understand.
  • Do not run the cycle with a doubtful contour.

When to call maintenance:

Normally requires no maintenance.

Reset/rearm:

Reset after correcting contour definition.

Confirmed: SINUMERIK 840D sl, diagnostics manual 07/2021 (6FC5398-6BP40-6BA5), p. 574, cycle alarm 61015 «Contour is not defined».

Sources

  • Official manual: SINUMERIK 840D sl / 828D Diagnostics Manual 07/2021 (6FC5398-6BP40-6BA5) · p. 574

Official documentation

Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.

Brand and control names belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, and this guide is not official documentation.

Frequently asked questions

What does alarm Siemens 61015 mean on Siemens?

The Siemens cycle cannot find the referenced contour to machine. It is an alarm from the Program area, and in the catalog it is listed as “Cycle: contour not defined”. On the machine you notice it like this: Fails when running the contour cycle, Cycle block message, Common after editing/renaming contours.

Why does alarm Siemens 61015 come up?

On the shop floor it almost always comes from one of these causes: Contour deleted or renamed, Badly defined labels, Inconsistent post. Rule out the most likely one on your machine first, before touching parameters or swapping anything.

How do you clear alarm Siemens 61015?

Reset after correcting contour definition. Resetting without fixing the cause first only hides the problem: Siemens 61015 trips again and, in the meantime, you keep working with the machine in bad shape.

What should I check first with alarm Siemens 61015?

With the machine stopped and in a safe state, start with these checks: Check the contour name/labels, Validate geometry in simulation, Check the post processor. That alone will tell you whether it is the program or whether you need to raise a maintenance job.

What should I NOT do with alarm Siemens 61015?

With Siemens 61015 active, avoid this: Do not delete blocks you do not understand, Do not run the cycle with a doubtful contour. Skipping any of these points is what turns a minor stop into an expensive breakdown.

When do I have to call maintenance for alarm Siemens 61015?

Normally requires no maintenance. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.

How serious is alarm Siemens 61015?

It is a stop alarm: the cycle will not continue until you fix the cause. It does not always mean serious damage, but it leaves the machine where it is and you have to check it before running again. Confirmed: SINUMERIK 840D sl, diagnostics manual 07/2021 (6FC5398-6BP40-6BA5), p. 574, cycle alarm 61015 «Contour is not defined».

More alarms for Siemens

See all alarms for this brand

Related apps