Siemens F30001 alarm: SINAMICS: overcurrent

The SINAMICS drive detects output current higher than the threshold (typically 200% nominal).

For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.

Control
Siemens
Machine
Milling, Turning, Mill-turn
Area
Servo / ejes
Severity
Critical

Symptoms

  • Immediate drive trip.
  • Eje/husillo deshabilitado.
  • Alarm 300500 in companion NCK.

Common causes

  • Short circuit in the motor or cable.
  • Fallo a tierra.
  • Motor parameters (p0304/p0305) incorrect.
  • Long cable without a filter.
  • Too aggressive acceleration ramp.

First safe checks

  1. 01Note F30001 and r0949 (sub-value).
  2. 02Do not re-energise repeatedly.
  3. 03Megger-test the motor/cable with the drive powered off.

What not to do

  • Do not retry the start-up repeatedly.
  • Do not work on an energised drive.
  • Do not raise current limits.

When to call maintenance:

Always: indicates electrical/engine problem.

Reset/rearm:

Reset only after verified repair.

Official documentation

Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.

Frequently Asked Questions (FAQ)

What does alarm Siemens F30001 mean on Siemens?

The SINAMICS drive detects output current higher than the threshold (typically 200% nominal). It is an alarm from the Servo / ejes area, and in the catalog it is listed as “SINAMICS: overcurrent”. On the machine you notice it like this: Immediate drive trip, Eje/husillo deshabilitado, Alarm 300500 in companion NCK.

Why does alarm Siemens F30001 come up?

On the shop floor it almost always comes from one of these causes: Short circuit in the motor or cable, Fallo a tierra, Motor parameters (p0304/p0305) incorrect, Long cable without a filter, Too aggressive acceleration ramp. Rule out the most likely one on your machine first, before touching parameters or swapping anything.

How do you clear alarm Siemens F30001?

Reset only after verified repair. Resetting without fixing the cause first only hides the problem: Siemens F30001 trips again and, in the meantime, you keep working with the machine in bad shape.

What should I check first with alarm Siemens F30001?

With the machine stopped and in a safe state, start with these checks: Note F30001 and r0949 (sub-value), Do not re-energise repeatedly, Megger-test the motor/cable with the drive powered off. That alone will tell you whether it is the program or whether you need to raise a maintenance job.

What should I NOT do with alarm Siemens F30001?

With Siemens F30001 active, avoid this: Do not retry the start-up repeatedly, Do not work on an energised drive, Do not raise current limits. Skipping any of these points is what turns a minor stop into an expensive breakdown.

When do I have to call maintenance for alarm Siemens F30001?

Always: indicates electrical/engine problem. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.

How serious is alarm Siemens F30001?

It is critical: there is a real risk of damage to the machine, the tool or a person. Leave the machine stopped, do not keep resetting it to see if it goes away, and call maintenance before producing again. Guidance reference. Always confirm the full text in the exact machine/control manual.