Siemens F30003 alarm: SINAMICS: DC link undervoltage

The SINAMICS drive detects insufficient voltage on the DC link during operation or startup.

For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.

Control
Siemens
Machine
Milling, Turning, Mill-turn
Area
Power supply
Severity
Critical

Symptoms

  • The drive disables.
  • Axis/spindle drops out when accelerating.
  • May appear with mains dips.

Common causes

  • Low feeding.
  • Line module.
  • Fusible/contactor.
  • Network drop under load.

First safe checks

  1. 01Note F30003 and r0949.
  2. 02Have qualified personnel check the mains.
  3. 03Revisar LEDs line module.

What not to do

  • Do not bypass safety devices.
  • Do not manipulate energized electrical cabinet.
  • Do not continue producing if the alarm reappears.

When to call maintenance:

Always, if it repeats.

Reset/rearm:

Reset after restoring stable power.

Official documentation

Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.

Frequently Asked Questions (FAQ)

What does alarm Siemens F30003 mean on Siemens?

The SINAMICS drive detects insufficient voltage on the DC link during operation or startup. It is an alarm from the Power supply area, and in the catalog it is listed as “SINAMICS: DC link undervoltage”. On the machine you notice it like this: The drive disables, Axis/spindle drops out when accelerating, May appear with mains dips.

Why does alarm Siemens F30003 come up?

On the shop floor it almost always comes from one of these causes: Low feeding, Line module, Fusible/contactor, Network drop under load. Rule out the most likely one on your machine first, before touching parameters or swapping anything.

How do you clear alarm Siemens F30003?

Reset after restoring stable power. Resetting without fixing the cause first only hides the problem: Siemens F30003 trips again and, in the meantime, you keep working with the machine in bad shape.

What should I check first with alarm Siemens F30003?

With the machine stopped and in a safe state, start with these checks: Note F30003 and r0949, Have qualified personnel check the mains, Revisar LEDs line module. That alone will tell you whether it is the program or whether you need to raise a maintenance job.

What should I NOT do with alarm Siemens F30003?

With Siemens F30003 active, avoid this: Do not bypass safety devices, Do not manipulate energized electrical cabinet, Do not continue producing if the alarm reappears. Skipping any of these points is what turns a minor stop into an expensive breakdown.

When do I have to call maintenance for alarm Siemens F30003?

Always, if it repeats. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.

How serious is alarm Siemens F30003?

It is critical: there is a real risk of damage to the machine, the tool or a person. Leave the machine stopped, do not keep resetting it to see if it goes away, and call maintenance before producing again. Guidance reference. Always confirm the full text in the exact machine/control manual.