Siemens F30005/F30011 alarm: SINAMICS: I2t overload or line phase failure
The SINAMICS power module is overloaded (I2t) or detects a line phase failure in the main circuit.
For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.
The brands and control names mentioned belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, ISO or ASME: this is our own content, not official documentation. Legal notice.
- Control
- Siemens
- Machine
- Milling, Turning, Mill-turn
- Area
- Servo / ejes
- Severity
- Critical
Symptoms
- Drive trip (OFF2).
- With F30005: appears after heavy cycles.
- With F30011: it may affect several axes at once.
Common causes
- Module rated current exceeded for too long.
- Duty cycle not respected.
- Blown fuse on one phase or a mains phase down.
- Supply phases badly unbalanced.
First safe checks
- 01Write down which fault it is (F30005 or F30011) and the axis.
- 02With F30005: check load and feeds.
- 03With F30011: have maintenance check fuses and mains voltage.
What not to do
- Do not keep producing after a reset without reducing the load.
- Do not raise current or thermal limits to keep running.
- Do not change fuses with the cabinet live.
When to call maintenance:
Always with F30011, and with F30005 if it repeats under normal load or with no load.
Reset/rearm:
Reset after correcting the load or the mains supply.
Confirmed: SINUMERIK 840D sl, diagnostics manual 07/2021 (6FC5398-6BP40-6BA5), SINAMICS alarms, pp. 1088-1089: 230005 (F30005) «Power unit: Overload I2t» and 230011 (F30011) «Power unit: Line phase failure in main circuit».
Sources
- Official manual: SINUMERIK 840D sl / 828D Diagnostics Manual 07/2021 (6FC5398-6BP40-6BA5) · pp. 1088-1089
Official documentation
Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.
Brand and control names belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, and this guide is not official documentation.
Frequently asked questions
What does alarm Siemens F30005/F30011 mean on Siemens?
The SINAMICS power module is overloaded (I2t) or detects a line phase failure in the main circuit. It is an alarm from the Servo / ejes area, and in the catalog it is listed as “SINAMICS: I2t overload or line phase failure”. On the machine you notice it like this: Drive trip (OFF2), With F30005: appears after heavy cycles, With F30011: it may affect several axes at once.
Why does alarm Siemens F30005/F30011 come up?
On the shop floor it almost always comes from one of these causes: Module rated current exceeded for too long, Duty cycle not respected, Blown fuse on one phase or a mains phase down, Supply phases badly unbalanced. Rule out the most likely one on your machine first, before touching parameters or swapping anything.
How do you clear alarm Siemens F30005/F30011?
Reset after correcting the load or the mains supply. Resetting without fixing the cause first only hides the problem: Siemens F30005/F30011 trips again and, in the meantime, you keep working with the machine in bad shape.
What should I check first with alarm Siemens F30005/F30011?
With the machine stopped and in a safe state, start with these checks: Write down which fault it is (F30005 or F30011) and the axis, With F30005: check load and feeds, With F30011: have maintenance check fuses and mains voltage. That alone will tell you whether it is the program or whether you need to raise a maintenance job.
What should I NOT do with alarm Siemens F30005/F30011?
With Siemens F30005/F30011 active, avoid this: Do not keep producing after a reset without reducing the load, Do not raise current or thermal limits to keep running, Do not change fuses with the cabinet live. Skipping any of these points is what turns a minor stop into an expensive breakdown.
When do I have to call maintenance for alarm Siemens F30005/F30011?
Always with F30011, and with F30005 if it repeats under normal load or with no load. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.
How serious is alarm Siemens F30005/F30011?
It is critical: there is a real risk of damage to the machine, the tool or a person. Leave the machine stopped, do not keep resetting it to see if it goes away, and call maintenance before producing again. Confirmed: SINUMERIK 840D sl, diagnostics manual 07/2021 (6FC5398-6BP40-6BA5), SINAMICS alarms, pp. 1088-1089: 230005 (F30005) «Power unit: Overload I2t» and 230011 (F30011) «Power unit: Line phase failure in main circuit».
More alarms for Siemens
Related apps
GSM Code List
List of G and M Codes for CNC Programming. Search and filter ISO commands by control, machine or function.
CNC G-code Simulator
CNC IDE: editing with G/M tooltips, line inspector, conversion between controls and 2D/3D toolpath.
Calculate cycle time
Estimate CNC turning and milling cycle time from G-code. Calculate parts per hour with a breakdown of cutting, rapids, canned cycles and tool changes.