Siemens F30015 alarm: SINAMICS: phase failure in motor cable

The SINAMICS drive detects a phase imbalance on the motor output.

For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.

The brands and control names mentioned belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, ISO or ASME: this is our own content, not official documentation. Legal notice.

Control
Siemens
Machine
Milling, Turning, Mill-turn
Area
Servo / ejes
Severity
Critical

Symptoms

  • The motor does not start or it vibrates.
  • Drive trip.
  • May appear when energising or under load.

Common causes

  • Motor cable with an open phase.
  • Output contactor stuck.
  • Motor winding damaged in one phase.

First safe checks

  1. 01Write down F30015.
  2. 02Check the connectors with the drive powered off.
  3. 03Measure phase-to-phase resistance (service).

What not to do

  • Do not bypass safety devices.
  • Do not manipulate energized electrical cabinet.
  • Do not continue producing if the alarm reappears.

When to call maintenance:

Always.

Reset/rearm:

Reset only after phase repair.

Confirmed: SINUMERIK 840D sl, diagnostics manual 07/2021 (6FC5398-6BP40-6BA5), SINAMICS alarms, p. 1091, fault 230015 (F30015) «Power unit: Phase failure motor cable».

Sources

  • Official manual: SINUMERIK 840D sl / 828D Diagnostics Manual 07/2021 (6FC5398-6BP40-6BA5) · p. 1091

Official documentation

Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.

Brand and control names belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, and this guide is not official documentation.

Frequently asked questions

What does alarm Siemens F30015 mean on Siemens?

The SINAMICS drive detects a phase imbalance on the motor output. It is an alarm from the Servo / ejes area, and in the catalog it is listed as “SINAMICS: phase failure in motor cable”. On the machine you notice it like this: The motor does not start or it vibrates, Drive trip, May appear when energising or under load.

Why does alarm Siemens F30015 come up?

On the shop floor it almost always comes from one of these causes: Motor cable with an open phase, Output contactor stuck, Motor winding damaged in one phase. Rule out the most likely one on your machine first, before touching parameters or swapping anything.

How do you clear alarm Siemens F30015?

Reset only after phase repair. Resetting without fixing the cause first only hides the problem: Siemens F30015 trips again and, in the meantime, you keep working with the machine in bad shape.

What should I check first with alarm Siemens F30015?

With the machine stopped and in a safe state, start with these checks: Write down F30015, Check the connectors with the drive powered off, Measure phase-to-phase resistance (service). That alone will tell you whether it is the program or whether you need to raise a maintenance job.

What should I NOT do with alarm Siemens F30015?

With Siemens F30015 active, avoid this: Do not bypass safety devices, Do not manipulate energized electrical cabinet, Do not continue producing if the alarm reappears. Skipping any of these points is what turns a minor stop into an expensive breakdown.

When do I have to call maintenance for alarm Siemens F30015?

Always. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.

How serious is alarm Siemens F30015?

It is critical: there is a real risk of damage to the machine, the tool or a person. Leave the machine stopped, do not keep resetting it to see if it goes away, and call maintenance before producing again. Confirmed: SINUMERIK 840D sl, diagnostics manual 07/2021 (6FC5398-6BP40-6BA5), SINAMICS alarms, p. 1091, fault 230015 (F30015) «Power unit: Phase failure motor cable».