Skip to content

Fanuc DS0001 alarm: Axis synchronization error (position deviation)

DS0001 appears on machines where two motors drive the same axis or two axes must always move together, such as a gantry with a motor on each side. The control has seen the position error of the master axis and that of the slave drift apart by more than allowed. It is a mechanical protection: ignore it and the gantry twists.

For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.

The brands and control names mentioned belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, ISO or ASME: this is our own content, not official documentation. Legal notice.

Control
Fanuc
Machine
Milling, Turning, Mill-turn
Area
Servo / ejes
Severity
Critical

Symptoms

  • A gantry or a pair of axes moving together (master and slave) stops.
  • It can appear on the master or the slave axis.
  • It usually appears when accelerating, braking or after a crash.

Common causes

  • One side of the gantry drags or jams (way, chips, bellows).
  • Different adjustment or wear of the ball screw between the two sides.
  • Faulty encoder or scale on one of the axes.
  • Misalignment after a crash or after replacing a motor.

First safe checks

  1. 01Write down which axis the alarm shows.
  2. 02Compare the master and slave position error on the diagnostics screen.
  3. 03Check the ways and covers on both sides without forcing the axis to move.

What not to do

  • Do not move one side of the gantry on its own.
  • Do not widen the synchronization limit just to keep working.
  • Do not work on energised drives.

When to call maintenance:

Whenever it repeats: an out-of-sync gantry can twist and damage the guideways and ball screws.

Reset/rearm:

Reset only once the cause has been found and removed; then check alignment with slow movement.

Fanuc manual 30i-B (B-64485EN/01, appendix A, p. 676) and 0i-F (B-64607EN/01, p. 408): DS0001 SYNC EXCESS ERROR (POS DEV); in feed axis synchronization the position error difference between master and slave exceeds parameter 8323.

Sources

  • Official manual: FANUC Series 0i-MODEL F Operation and Maintenance Handbook (B-64607EN/01) · p. 408
  • Official manual: FANUC Series 30i/31i/32i-MODEL B Maintenance Manual (B-64485EN/01) · p. 676

Official documentation

Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.

Brand and control names belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, and this guide is not official documentation.

What happens on the machine

In feed axis synchronous control the CNC sends the same motion to two servos, the master and the slave, and each has its own position error, the difference between where it should be and where its encoder says it is. On a healthy machine the two errors are almost identical, because both sides carry the same load and have the same tuning. The control watches the difference between them and, if it exceeds the value of parameter 8323, stops with DS0001, which may be reported on the master or on the slave. The two errors separating means one side moves with more difficulty than the other, or one of the two is not measuring correctly. The first is the most common: a guideway with chips or no lubrication on one side, a bellows or cover that rubs, a damaged carriage, or one ball screw stiffer than the other. The second shows up with a faulty encoder or scale, or after a motor has been replaced without redoing the alignment. A crash leaves the same symptom too, because it shifts one side relative to the other. Since both sides are tied together by a rigid structure, any difference turns into stress on guideways and screws.

Step-by-step diagnosis

In order, from the fastest and cheapest check to the most expensive.

  1. 01Note which axis it reports and when it tripped

    The alarm names the axis where it was detected. Note whether it was at start-up, accelerating, braking or in a particular part of the travel. If it is always at the same point, look for something physical in that section.

  2. 02Compare the position errors of both sides

    The servo diagnostic screen shows the position error of each axis. Jog slowly and watch both: if one rises much more than the other over a section, that side has more resistance.

  3. 03Inspect guideways, bellows and covers on both sides

    With the machine stopped and locked out, inspect both sides: built-up chips, lubrication, torn or pinched bellows, cover screws that rub. The cause is usually on one side only and can be seen by eye.

  4. 04Think about recent changes

    A crash, replacing a motor, amplifier or encoder, or work on the guideways can misalign the sides. If the alarm started right afterwards, the alignment check belongs to maintenance or the builder.

  5. 05Do not split the axes to move them

    Never move one side on its own to straighten the gantry and never widen the synchronisation limit. If alignment is needed, it is done with the builder's procedure and the right people.

Typical cases

It always trips at the same end of the gantry travel.

There is resistance in that section on one side: chips built up at the end of the guideway or a bellows that folds badly. Confirm it with the higher position error on that side and fix it by cleaning and repairing the cover.

It started after a light crash of the head.

The impact shifted one side relative to the other or damaged a coupling. Confirm it because the difference appears even moving without load. It needs an alignment check by maintenance before production resumes.

It appears randomly at any position and without load.

A measuring fault on one side, such as an encoder, a scale or its cable. Confirm it by jumps in position error unrelated to the motion. It is a maintenance diagnosis with the servo manual.

How to stop it coming back

Clean and lubricate the guideways on both sides equally, not just the visible one. Inspect bellows and covers as part of periodic maintenance, because one rubbing bellows is enough to unbalance the gantry. After any crash, motor replacement or guideway work, check alignment before producing. And leave the synchronisation limit as the builder set it: it is the protection that stops the structure twisting.

Frequently asked questions

What does alarm DS0001 mean on Fanuc?

In synchronous control of feed axes, the position error difference between the master and slave axis exceeds the limit set in Fanuc. It is an alarm from the Servo / ejes area, and in the catalog it is listed as “Axis synchronization error (position deviation)”. On the machine you notice it like this: A gantry or a pair of axes moving together (master and slave) stops, It can appear on the master or the slave axis, It usually appears when accelerating, braking or after a crash.

Why does alarm DS0001 come up?

On the shop floor it almost always comes from one of these causes: One side of the gantry drags or jams (way, chips, bellows), Different adjustment or wear of the ball screw between the two sides, Faulty encoder or scale on one of the axes, Misalignment after a crash or after replacing a motor. Rule out the most likely one on your machine first, before touching parameters or swapping anything.

How do you clear alarm DS0001?

Reset only once the cause has been found and removed; then check alignment with slow movement. Resetting without fixing the cause first only hides the problem: DS0001 trips again and, in the meantime, you keep working with the machine in bad shape.

What should I check first with alarm DS0001?

With the machine stopped and in a safe state, start with these checks: Write down which axis the alarm shows, Compare the master and slave position error on the diagnostics screen, Check the ways and covers on both sides without forcing the axis to move. That alone will tell you whether it is the program or whether you need to raise a maintenance job.

What should I NOT do with alarm DS0001?

With DS0001 active, avoid this: Do not move one side of the gantry on its own, Do not widen the synchronization limit just to keep working, Do not work on energised drives. Skipping any of these points is what turns a minor stop into an expensive breakdown.

When do I have to call maintenance for alarm DS0001?

Whenever it repeats: an out-of-sync gantry can twist and damage the guideways and ball screws. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.

How serious is alarm DS0001?

It is critical: there is a real risk of damage to the machine, the tool or a person. Leave the machine stopped, do not keep resetting it to see if it goes away, and call maintenance before producing again. Fanuc manual 30i-B (B-64485EN/01, appendix A, p. 676) and 0i-F (B-64607EN/01, p. 408): DS0001 SYNC EXCESS ERROR (POS DEV); in feed axis synchronization the position error difference between master and slave exceeds parameter 8323.