01Write down the axis, the full number and the sub-code
SV0414 on its own is not enough: you need the axis and the detail shown on the servo diagnostic screen. On many series that information sits in the diagnostic numbers around the 200 range, but the exact location changes between series, so look it up in your control's maintenance manual as servo alarm diagnostics. That figure is the first thing the service engineer will ask you for.
02Pay attention to when it appears
At power-up with nothing moving points at supply, parameters or hardware. When motion starts, at power or feedback. Only during hard acceleration or braking, at overcurrent or bus voltage. Only after hours of running, at temperature or a contact that degrades as it warms up. This information is worth as much as the sub-code.
03Repeat the full power-down cycle
Power down by the procedure, wait as long as the builder specifies and switch back on. If the fault was transient it goes away. If it comes back with the machine at rest and nothing having moved, it is a hard fault and there is no point resetting again: every retry with a hard power fault is added risk.
04Reconstruct what was touched beforehand
A motor or amplifier change, parameters restored from a backup, a cable replacement, electrical work in the cabinet, a storm. An SV0414 that shows up right after an intervention is usually a parameter that does not match the hardware or a connector not properly seated, not a new failure.
05Rule out the axis being mechanically jammed
If the axis can be moved safely, check in jog at low feed that it turns freely with no tight spots. A jammed axis forces the amplifier to full current and can cause overcurrent detection. If it is jammed, you have your starting point and it is mechanical, not electronic.
06Hand the case to maintenance with the data in order
Axis, number and sub-code, exactly when it appears, what was touched beforehand and whether there are other simultaneous alarms. From here on, measuring cables, checking the amplifier, comparing servo parameters against the builder's copy or replacing components is electrical maintenance work with the machine locked out and with a parameter backup taken first.