Skip to content

Fanuc PS0073 alarm: Program number already in use

The control is trying to store a program under an O number that is already taken in memory, and it refuses to overwrite it. It happens when loading from USB, a memory card, RS232 or DNC, or when creating or renumbering a program in the editor. No axis moves: it is a program management message, but how you resolve it decides whether you keep the good version or lose it.

For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.

The brands and control names mentioned belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, ISO or ASME: this is our own content, not official documentation. Legal notice.

Control
Fanuc
Machine
Milling, Turning, Mill-turn
Area
Program
Severity
Stop

Symptoms

  • Fails when loading a program via USB, card, RS232 or DNC.
  • It appears when creating or renumbering a program in the editor.

Common causes

  • A program with that O number is already stored.
  • A new version is loaded without deleting the old one.
  • Post processor that always outputs the same O number.

First safe checks

  1. 01Look up that number in the program directory.
  2. 02Compare the saved program with the one you want to load.
  3. 03Decide which version is the good one before deleting or renumbering.

What not to do

  • Don't delete the old program without knowing whether another job uses it as a subprogram.
  • Do not renumber subprograms without checking all M98 calls.

When to call maintenance:

If the directory shows programs that should not be there or the memory does not list the existing ones correctly.

Reset/rearm:

Reset and repeat the load after deleting, renumbering or replacing the duplicate program.

Fanuc 0i-F manual (B-64607EN/01, ch. 8, p. 353): PS0073 PROGRAM NUMBER ALREADY IN USE, the program number is already in use. Same on 0i-D (B-64305EN) and as 073 on 0i-C (B-64115EN, p. 512).

Sources

  • Official manual: FANUC Series 0i-MODEL F Operation and Maintenance Handbook (B-64607EN/01) · p. 353
  • Official manual: FANUC Series 0i/0i Mate-MODEL C Maintenance Manual (B-64115EN) · p. 512
  • Official manual: FANUC Series 0i-MODEL D Maintenance Manual (B-64305EN)

Official documentation

Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.

Brand and control names belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, and this guide is not official documentation.

What happens on the machine

Fanuc identifies every program in memory by its O number, and the directory does not allow two programs with the same number. When a new one arrives with a number that is already taken, the control stops the registration and shows PS0073 instead of replacing the old one. It is a deliberate protection: the control has no way of knowing whether what is arriving is a corrected version of the same job or a completely different program that someone gave the same number. The alarm almost always appears in three situations. First, reloading a new version of a job without deleting the old one, which is very normal when a dimension is corrected in CAM and the program is sent again. Second, a post processor or a template that always writes the same program number, so two different jobs end up colliding on the machine. Third, renumbering a program in the control's editor to a number that is already in use, often by a common subprogram nobody remembered. In all three the quick fix is to delete whatever is in the way, and that is where the risk lies: if what held the number was a subprogram other jobs call, or the only good copy of a part, the problem will show up later and far away from this alarm.

Step-by-step diagnosis

In order, from the fastest and cheapest check to the most expensive.

  1. 01Write down the number you were trying to store

    Look at the O number of the program being loaded or created. If it comes from a file, open it on the PC and check the first line: sometimes the file name and the O number inside it do not match, and the control goes by the one inside.

  2. 02Find that number in the control's directory

    List the programs and locate the one already holding that number. Look at the comment on the first line, the size and, if the control shows it, the date. That tells you whether it is another version of the same job or something different.

  3. 03Compare the content before deciding

    Open the stored program and compare the first lines, the tools it calls and a known dimension with the one you want to load. If they are the same job, decide which one is good together with whoever programmed it. If it is a common shop subprogram, leave it alone.

  4. 04Choose: replace, renumber or cancel

    If it is a new version of the same job, back up the old one, delete it and load the new one. If it is a different job, load the new one under a free number and, if it is a subprogram, correct every M98 call that uses it. If it is not clear, load nothing until it is.

  5. 05If it keeps happening with different jobs, check the post processor

    When two unrelated programs always come out with the same number, the problem is in CAM or in the post template. Fix it there so every job gets its own number and the conflict does not follow you into every load.

Typical cases

A dimension is corrected in CAM, the program is sent again and the control gives PS0073.

The old version is still in memory under the same number. Confirm it by reading the comment and comparing the corrected dimension. Resolve it by backing up the old one, deleting it and loading the new one, and noting which version is left on the machine.

Two different parts come out of CAM with the same program number and the second one will not load.

The post processor always numbers the same way. Confirm it because every new job carries that number. Fix it in the post template and, meanwhile, renumber by hand before sending, without touching the part already on the machine.

Renumbering a program in the editor triggers the alarm with a number that looked free.

That number belongs to a common subprogram that was not recognised in the list. Confirm it by opening it. Pick another number and leave the subprogram intact, because other jobs call it with M98.

How to stop it coming back

A written numbering rule posted at the machine: one range reserved for common subprograms, another for production and another for tests. Have the post processor assign the number from the job rather than a fixed one. Back up the directory before deleting anything to make room for a new version. And one simple habit: put a comment with the part and the version on the first line of every program, so that when PS0073 appears anyone can tell in seconds what is stored under that number.

Frequently asked questions

What does alarm PS0073 mean on Fanuc?

Fanuc won't register a program because another one with the same O number already exists in memory. It is an alarm from the Program area, and in the catalog it is listed as “Program number already in use”. On the machine you notice it like this: Fails when loading a program via USB, card, RS232 or DNC, It appears when creating or renumbering a program in the editor.

Why does alarm PS0073 come up?

On the shop floor it almost always comes from one of these causes: A program with that O number is already stored, A new version is loaded without deleting the old one, Post processor that always outputs the same O number. Rule out the most likely one on your machine first, before touching parameters or swapping anything.

How do you clear alarm PS0073?

Reset and repeat the load after deleting, renumbering or replacing the duplicate program. Resetting without fixing the cause first only hides the problem: PS0073 trips again and, in the meantime, you keep working with the machine in bad shape.

What should I check first with alarm PS0073?

With the machine stopped and in a safe state, start with these checks: Look up that number in the program directory, Compare the saved program with the one you want to load, Decide which version is the good one before deleting or renumbering. That alone will tell you whether it is the program or whether you need to raise a maintenance job.

What should I NOT do with alarm PS0073?

With PS0073 active, avoid this: Don't delete the old program without knowing whether another job uses it as a subprogram, Do not renumber subprograms without checking all M98 calls. Skipping any of these points is what turns a minor stop into an expensive breakdown.

When do I have to call maintenance for alarm PS0073?

If the directory shows programs that should not be there or the memory does not list the existing ones correctly. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.

How serious is alarm PS0073?

It is a stop alarm: the cycle will not continue until you fix the cause. It does not always mean serious damage, but it leaves the machine where it is and you have to check it before running again. Fanuc 0i-F manual (B-64607EN/01, ch. 8, p. 353): PS0073 PROGRAM NUMBER ALREADY IN USE, the program number is already in use. Same on 0i-D (B-64305EN) and as 073 on 0i-C (B-64115EN, p. 512).

More alarms for Fanuc

See all alarms for this brand