01Write down the number you were trying to store
Look at the O number of the program being loaded or created. If it comes from a file, open it on the PC and check the first line: sometimes the file name and the O number inside it do not match, and the control goes by the one inside.
02Find that number in the control's directory
List the programs and locate the one already holding that number. Look at the comment on the first line, the size and, if the control shows it, the date. That tells you whether it is another version of the same job or something different.
03Compare the content before deciding
Open the stored program and compare the first lines, the tools it calls and a known dimension with the one you want to load. If they are the same job, decide which one is good together with whoever programmed it. If it is a common shop subprogram, leave it alone.
04Choose: replace, renumber or cancel
If it is a new version of the same job, back up the old one, delete it and load the new one. If it is a different job, load the new one under a free number and, if it is a subprogram, correct every M98 call that uses it. If it is not clear, load nothing until it is.
05If it keeps happening with different jobs, check the post processor
When two unrelated programs always come out with the same number, the problem is in CAM or in the post template. Fix it there so every job gets its own number and the conflict does not follow you into every load.