01Walk the safety chain before touching anything else
Emergency stops at every station, including the one on the pendant and the one round the back that nobody looks at. Enclosure doors properly closed. Any loader or peripheral interlock. Reset whatever is pressed using the machine's normal procedure. This clears a large share of SV0401s and costs nothing. Never bypass an interlock to test.
02Note the axis and whether other alarms came up at the same time
If a single axis is named, write down which one. If several come up together, you already know it is not one motor: it is a common supply or the safety chain. If SV0401 appears alongside servo bus or power supply module alarms, those outrank it and have to be dealt with first.
03Power down and back up using the full procedure
A clean restart, following the machine builder's sequence and respecting the waiting time between off and on. If the fault was a supply transient or an incomplete bus charge, it goes away and stays away. If it comes straight back on power-up, it is a hard fault and it will not be solved from the operator panel.
04Ask what happened just before
A power cut, a storm, welding nearby, an axis crash, an amplifier swap or recent electrical work are all direct leads. An SV0401 that shows up the morning after work inside the cabinet almost always points at a connector left loose or a phase put back wrong.
05Hand the electrical diagnosis to maintenance
The status LEDs and displays on the amplifiers and the power supply module are the next useful piece of information, but reading them means opening the cabinet, and that is electrical maintenance work with the machine locked out, not an operator job. Same for fuses, control voltages and contactor states. Your part ends with a good description of the symptom: which axis, since when, whether it happens at power-up or during the job, and what was done beforehand.