Fanuc PS0071/PS0072/PS0079 alarm: Data not found, too many programs or verification failed

A family of program management messages: the data searched for does not turn up, the number of programs memory allows has been exceeded, or the verification between what was sent and what was stored does not match. None of them is a machine fault, but they all share the same trap: the quick fix is usually to delete, and deleting without a backup is how programs get lost.

For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.

The brands and control names mentioned belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, ISO or ASME: this is our own content, not official documentation. Legal notice.

Control
Fanuc
Machine
Milling, Turning, Mill-turn
Area
Program
Severity
Warning

Symptoms

  • Does not load or save program.
  • Fails when verifying the transfer.
  • The program you are looking for doesn't appear or no more programs can be saved.

Common causes

  • Search for an O or N number that does not exist.
  • Too many programs stored (series limit).
  • Incomplete DNC/RS232 transfer.
  • Program modified after the last backup.

First safe checks

  1. 01Make a backup before deleting.
  2. 02Compare the source file with the control.
  3. 03Repeat transfer with correct parameters.

What not to do

  • Do not delete memory without backup.
  • Do not overwrite production programs without checking differences.

When to call maintenance:

If memory does not list existing programs or checks fail with correct cables/parameters.

Reset/rearm:

Reset after correcting memory, program number or transfer.

Fanuc 0i-F manual (B-64607EN/01, ch. 8, p. 352-353): PS0071 DATA NOT FOUND, PS0072 TOO MANY PROGRAMS (400 on 1 channel, 800 on 2 channels) and PS0079 PROGRAM NOT MATCH. On 0i-C (B-64115EN, p. 512) they are 071, 072 and 079 PROGRAM VERIFY ERROR.

Sources

  • Official manual: FANUC Series 0i-MODEL F Operation and Maintenance Handbook (B-64607EN/01) · p. 352-353
  • Official manual: FANUC Series 0i/0i Mate-MODEL C Maintenance Manual (B-64115EN) · p. 512

Official documentation

Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.

Brand and control names belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, and this guide is not official documentation.

What happens on the machine

The control's program memory is a store with two independent limits: total space and the maximum number of registered programs. When the maximum count is reached (on the 0i-F, 400 programs with one path or 800 with two) PS0072 appears even if free space remains. PS0071 is something else: the control searched for an address, a program number or a restart block and did not find it. Verification is the third: when a program is transferred, what is in the control can be compared character by character against the source; if a difference turns up, the control flags it. And that is where the useful information in this family lies: a failed verification almost never means the control is wrong, it means the transfer introduced an error. When that happens on the serial channel, the cause is usually noise, a cable in poor condition, or badly configured flow control that loses characters when the control falls behind processing. A program that has come through a transfer with errors can look perfectly normal and have one dimension changed in the middle, which is exactly the kind of fault you discover with the tool inside the part. So verification is not a formality: it is what separates a transferred program from a correctly transferred program.

Step-by-step diagnosis

In order, from the fastest and cheapest check to the most expensive.

  1. 01Classify what the control is telling you

    Not finding a piece of data (0071), not fitting any more programs (0072) and verification not matching (0079) are three different things. Note the exact alarm number and look its meaning up in your series' manual. The treatment is different in each case.

  2. 02If no more programs fit, back up before touching anything

    Get every program out to the server or a card and check the copy is complete. Only then decide what to delete, one at a time and deliberately. The shop's common subprograms are not touched, however old they look.

  3. 03If the data is not found, check what was searched for and where

    With 0071 the control searched for a program number, an address or the restart block and did not find it. Check the number as written, leading zeros included, and which device is being searched: internal memory, card and server do not see each other. If it was looking for a block to restart from, confirm that block number exists in that version of the program.

  4. 04If verification fails, do not run that program

    A program that does not verify very probably has some character different from the original, and that could be a dimension. Delete it and transfer it again. If verification fails again, the problem is the link, not the file.

  5. 05Attack the link if verification fails repeatedly

    Lower the baud rate at both ends, check parity and flow control, try another cable and check it does not run alongside power lines. If it verifies correctly at low speed, you have noise or a cable in poor condition, even if it works for now.

  6. 06If memory does not behave as it should, tell maintenance

    If deleting does not free space, if the control reports less capacity than it should, or if corrupt programs appear with nobody having touched them, there may be a memory or control battery problem. With a backup in hand, let maintenance look at it.

Typical cases

Verification always fails at roughly the same point in the transfer.

Noise or badly set flow control losing characters. Confirm it by lowering the baud rate and seeing whether it then verifies. Fix it by setting up the communication and reviewing the cable route and condition.

Searching for a program gives data not found although the operator swears it was loaded.

The program is on another device or was loaded under a different number. Confirm it by checking the different devices and comparing the number with the source file. It is solved by searching on the right device or loading it under the number the job calls.

Memory fills up and warnings appear every few weeks.

Accumulation of versions and tests with no clean-up policy. Confirm it by listing the directory. Fix it with automatic backup to the server and scheduled clean-ups, plus a numbering convention that distinguishes production from tests.

How to stop it coming back

Always verify transfers, not just send them, and never run a program that has not verified. Automatic backup of each machine's programs to the server. A numbering convention separating common subprograms, production and tests. Scheduled memory clean-ups with a backup taken first. And migrate to card or network wherever the machine allows, which removes serial channel verification problems at the root.

Frequently asked questions

What does alarm PS0071/PS0072/PS0079 mean on Fanuc?

Fanuc cannot find the searched address or program (0071), has reached the maximum number of programs (0072) or the compared program does not match the one in memory (0079). It is an alarm from the Program area, and in the catalog it is listed as “Data not found, too many programs or verification failed”. On the machine you notice it like this: Does not load or save program, Fails when verifying the transfer, The program you are looking for doesn't appear or no more programs can be saved.

Why does alarm PS0071/PS0072/PS0079 come up?

On the shop floor it almost always comes from one of these causes: Search for an O or N number that does not exist, Too many programs stored (series limit), Incomplete DNC/RS232 transfer, Program modified after the last backup. Rule out the most likely one on your machine first, before touching parameters or swapping anything.

How do you clear alarm PS0071/PS0072/PS0079?

Reset after correcting memory, program number or transfer. Resetting without fixing the cause first only hides the problem: PS0071/PS0072/PS0079 trips again and, in the meantime, you keep working with the machine in bad shape.

What should I check first with alarm PS0071/PS0072/PS0079?

With the machine stopped and in a safe state, start with these checks: Make a backup before deleting, Compare the source file with the control, Repeat transfer with correct parameters. That alone will tell you whether it is the program or whether you need to raise a maintenance job.

What should I NOT do with alarm PS0071/PS0072/PS0079?

With PS0071/PS0072/PS0079 active, avoid this: Do not delete memory without backup, Do not overwrite production programs without checking differences. Skipping any of these points is what turns a minor stop into an expensive breakdown.

When do I have to call maintenance for alarm PS0071/PS0072/PS0079?

If memory does not list existing programs or checks fail with correct cables/parameters. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.

How serious is alarm PS0071/PS0072/PS0079?

It is a warning: the machine carries on, but it is flagging something that will get worse if you let it go. Deal with it between parts, not at the end of the shift. Fanuc 0i-F manual (B-64607EN/01, ch. 8, p. 352-353): PS0071 DATA NOT FOUND, PS0072 TOO MANY PROGRAMS (400 on 1 channel, 800 on 2 channels) and PS0079 PROGRAM NOT MATCH. On 0i-C (B-64115EN, p. 512) they are 071, 072 and 079 PROGRAM VERIFY ERROR.