01Classify what the control is telling you
Not finding a piece of data (0071), not fitting any more programs (0072) and verification not matching (0079) are three different things. Note the exact alarm number and look its meaning up in your series' manual. The treatment is different in each case.
02If no more programs fit, back up before touching anything
Get every program out to the server or a card and check the copy is complete. Only then decide what to delete, one at a time and deliberately. The shop's common subprograms are not touched, however old they look.
03If the data is not found, check what was searched for and where
With 0071 the control searched for a program number, an address or the restart block and did not find it. Check the number as written, leading zeros included, and which device is being searched: internal memory, card and server do not see each other. If it was looking for a block to restart from, confirm that block number exists in that version of the program.
04If verification fails, do not run that program
A program that does not verify very probably has some character different from the original, and that could be a dimension. Delete it and transfer it again. If verification fails again, the problem is the link, not the file.
05Attack the link if verification fails repeatedly
Lower the baud rate at both ends, check parity and flow control, try another cable and check it does not run alongside power lines. If it verifies correctly at low speed, you have noise or a cable in poor condition, even if it works for now.
06If memory does not behave as it should, tell maintenance
If deleting does not free space, if the control reports less capacity than it should, or if corrupt programs appear with nobody having touched them, there may be a memory or control battery problem. With a backup in hand, let maintenance look at it.