Skip to content

Fanuc PS011/PS014 alarm: Zero feedrate or G95 not available

These are two program alarms from Fanuc's older family (0i-C, 16i/18i), grouped because both are about the feedrate. 011 says there is a cutting move without a valid feedrate. 014 says, on a mill, that feed per revolution (G95) was requested without the option, and on a lathe that the lead of a variable lead thread is out of range. Neither moves the machine: it stops while reading the block.

For reference only: alarms change with the manufacturer, the control and the machine PLC. Check the full code in the official manual before doing anything. Legal notice.

The brands and control names mentioned belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, ISO or ASME: this is our own content, not official documentation. Legal notice.

Control
Fanuc
Machine
Milling, Turning, Mill-turn
Area
Program
Severity
Stop

Symptoms

  • Stops at the first G01, G02 or G03 of the program or after a mode change.
  • It appears when using G95 on a milling machine or a variable pitch thread on a lathe.

Common causes

  • The F is missing before the first cutting move.
  • F0 or a feed value that is not valid for the active G94/G95 mode.
  • G95 without the feed per revolution or threading option.
  • On lathes, variable thread pitch (K address) out of range.

First safe checks

  1. 01Look for the last F programmed before the block.
  2. 02Check whether G94 or G95 is active.
  3. 03Confirm if the option exists on that machine.

What not to do

  • Do not bypass safety devices.
  • Do not manipulate energized electrical cabinet.
  • Do not continue producing if the alarm reappears.

When to call maintenance:

If the program has the correct feedrate and the control still won't accept the feed per revolution that used to work.

Reset/rearm:

Reset after adding or correcting the F and go back to the program's safe start.

Fanuc 0i-C manual (B-64115EN, alarm appendix, p. 508): 011 NO FEEDRATE COMMANDED (feedrate not programmed or inadequate) and 014 CAN NOT COMMAND G95 on mills (ILLEGAL LEAD COMMAND on lathes). On 0i-D/0i-F/30i-B the equivalent is PS0011 FEED ZERO (COMMAND).

Sources

  • Official manual: FANUC Series 0i/0i Mate-MODEL C Maintenance Manual (B-64115EN) · p. 508

Official documentation

Choose the manual matching your control series, software version and machine builder. A support portal is a starting point; it does not establish applicability to every model.

Brand and control names belong to their owners and are used only to identify the equipment. GetGCode is not affiliated with or endorsed by any manufacturer, and this guide is not official documentation.

What happens on the machine

Every cutting move (G01, G02, G03 and the cycles that use them) needs a feedrate, and on Fanuc F is modal: it is programmed once and stays valid for the following blocks until changed. If the control reaches the first cutting move without any valid F in force, it cannot work out how fast to move and raises 011 NO FEEDRATE COMMANDED; on the newer series (0i-D, 0i-F, 30i) the equivalent is PS0011 FEED ZERO. It happens mostly when the program is started from the middle, skipping the block that held the F, when a post processor writes F only when its value changes and the first move is left without one, or when a macro variable that should supply the feed arrives empty or at zero. 014 is different: on a mill, G95 programs feed in millimetres per spindle revolution, which requires the control to read the spindle position with an encoder and to have the synchronous feed or threading function. If the machine lacks that option, the control rejects G95 with CAN NOT COMMAND G95. On a lathe the same number 014 appears as ILLEGAL LEAD COMMAND in variable lead threading, when the lead increment or decrement given with address K exceeds the maximum value.

Step-by-step diagnosis

In order, from the fastest and cheapest check to the most expensive.

  1. 01Read the exact number and the machine type

    A 011 and a 014 are not fixed the same way. Note which one it is and the block it stopped on. For 014 it matters whether it is a mill or a lathe, because the meaning changes.

  2. 02For 011, find the last F before the block

    Scroll up from the alarm block until you find the last F. If there is none before the first cutting move, it is missing from the program. If there is one but you started from a later block, the control never read it: start from a point that includes it.

  3. 03Check variables and feed mode

    If F comes from a macro variable, look at its value on the variables screen at the moment of the fault. Also check whether G94 or G95 is active, because a sensible F value is very different in millimetres per minute and per revolution.

  4. 04For 014 on a mill, confirm the option

    Look in the control's option list for feed per revolution or synchronous threading. If it is not there, the program has to use G94 with the feed converted to millimetres per minute, calculated from that operation's rpm.

  5. 05For 014 on a lathe, check the variable lead

    Check the K value in the variable lead threading block and the starting lead. If the accumulated increment takes the lead beyond the maximum the control accepts, the thread has to be recalculated.

Typical cases

The program runs fine from the start but gives 011 when restarted from the middle.

The restart block comes after the only F in the program. Confirm it because it does not fail from the start. Fix it by putting F on the first move of every operation so any starting point is safe.

A program brought from another machine with G95 gives 014 on a basic mill.

The machine does not have the feed per revolution option. Confirm it in the option list. Post it for that machine with G94 and feed in millimetres per minute.

A builder's macro cycle gives 011 intermittently.

The variable that passes the feed arrives at zero when the operator leaves an argument blank. Confirm it by looking at the variable when the alarm trips and fix it by completing the call.

How to stop it coming back

Have the post processor write F on the first cutting move of every operation, even if the value does not change, so restarting from any operation is safe. One post processor per machine that knows whether it has feed per revolution. In macros, check at the start that feed arguments have a value and stop with your own message if they do not. And for variable lead threads, calculate the final lead before programming instead of trusting the control to accept it.

Frequently asked questions

What does alarm PS011/PS014 mean on Fanuc?

Fanuc stops the program because a cutting move has no valid F feedrate (011) or because G95 feed per revolution is requested without the required option (014). It is an alarm from the Program area, and in the catalog it is listed as “Zero feedrate or G95 not available”. On the machine you notice it like this: Stops at the first G01, G02 or G03 of the program or after a mode change, It appears when using G95 on a milling machine or a variable pitch thread on a lathe.

Why does alarm PS011/PS014 come up?

On the shop floor it almost always comes from one of these causes: The F is missing before the first cutting move, F0 or a feed value that is not valid for the active G94/G95 mode, G95 without the feed per revolution or threading option, On lathes, variable thread pitch (K address) out of range. Rule out the most likely one on your machine first, before touching parameters or swapping anything.

How do you clear alarm PS011/PS014?

Reset after adding or correcting the F and go back to the program's safe start. Resetting without fixing the cause first only hides the problem: PS011/PS014 trips again and, in the meantime, you keep working with the machine in bad shape.

What should I check first with alarm PS011/PS014?

With the machine stopped and in a safe state, start with these checks: Look for the last F programmed before the block, Check whether G94 or G95 is active, Confirm if the option exists on that machine. That alone will tell you whether it is the program or whether you need to raise a maintenance job.

What should I NOT do with alarm PS011/PS014?

With PS011/PS014 active, avoid this: Do not bypass safety devices, Do not manipulate energized electrical cabinet, Do not continue producing if the alarm reappears. Skipping any of these points is what turns a minor stop into an expensive breakdown.

When do I have to call maintenance for alarm PS011/PS014?

If the program has the correct feedrate and the control still won't accept the feed per revolution that used to work. If you are not sure how far it goes, stop the machine and report it: a repeat alarm always works out cheaper than a crash.

How serious is alarm PS011/PS014?

It is a stop alarm: the cycle will not continue until you fix the cause. It does not always mean serious damage, but it leaves the machine where it is and you have to check it before running again. Fanuc 0i-C manual (B-64115EN, alarm appendix, p. 508): 011 NO FEEDRATE COMMANDED (feedrate not programmed or inadequate) and 014 CAN NOT COMMAND G95 on mills (ILLEGAL LEAD COMMAND on lathes). On 0i-D/0i-F/30i-B the equivalent is PS0011 FEED ZERO (COMMAND).