01Identify the axis and whether it is on enabling or on homing
If the alarm comes up at power-up or when trying to enable the axes, it is the servo ready side. If it comes up while the reference return is running, it is the homing sequence. Each leads somewhere different, so this separation comes first.
02Check the safety chain and the machine state
Emergency stops, doors, interlocks, the mode selected on the panel. Many enable conditions depend on the machine being in a specific state. Reset whatever is pressed by the normal procedure, bypassing nothing.
03If it is a reference problem, watch the axis behaviour
See whether it decelerates on entering the reference area or runs straight past, whether it is trying from a position that is too close, or whether it is going the wrong way. Move the axis away and repeat by the normal procedure with the travel clear: if it works second time, it was the starting position.
04Check for PMC or machine alarms in parallel
Many of these conditions originate in the builder's logic. If the control shows machine-specific messages alongside the servo alarm, those usually explain better what is missing: a pressure, a clamp, the position of some device.
05Repeat the power cycle once
A clean restart separates a transient from a hard fault. If after the restart the axis enables and homes correctly, log it as an incident and watch whether it repeats. If it comes back the same, stop retrying and collect data.
06Signals, dogs and reference parameters: maintenance
Checking the deceleration signal, the state of a detector, the enable logic or the reference sequence parameters is maintenance work, with the machine locked out for the mechanical side and with a backup taken first for the parameter side. Afterwards zero has to be verified against a known point.